Doi : 10.1016/j.otsr.2019.10.019 
Craig Andrew Brownlie , Rob Evans, David Morrison, Alex Hayes, Swithin Song, Markus Stefan Kuster
 Orthopaedics department, Royal Perth hospital, 197, Wellington St, 6000 Perth, WA, Australia 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Anterior hip pain after total hip replacement (THR) can be caused by iliopsoas impingement (IPI). Validation of CT measured cup version is well published; however quantification of the anterior cup prominence has not been validated. Therefore, we did an in vitro study aiming to: (1) assess the accuracy of the current method of measuring the prominence of the acetabular component using a dry bone model; (2) develop a CT protocol based on bony anatomical landmarks that improves the accuracy of these measurements.

Hypothesis

We hypothesise that utilising reproducible anatomical landmarks on the acetabulum will improve the accuracy of measurement of anterior prominence at the psoas valley.

Methods

A dry bone pelvic model was implanted with bilateral acetabular cups. The cup was manipulated into ten different combinations of inclination and version, and anterior prominence directly measured in relation to the acetabular rim. A CT scan was performed for each position. Anterior prominence was then measured by two radiologists, first using standard methods (axial slice at level of centre of femoral head) and then again using a novel protocol (based on the position of the psoas valley in relation to the inferior medial acetabular notch).

Results

Mean errors between direct measurement of anterior prominence and radiologist reported measurements using standard protocol were 6.94mm±5.24 (SD) (95%Confidence Interval: 3.25–4.27) and 5.14mm±3.07 (95%CI: 1.9–2.5) with a tendency towards overestimation of prominence. Using an anatomical landmark based protocol; mean error was reduced to 3.0mm±1.9 (95%CI: 1.16–1.53) and 4.3mm±4.3 (95%CI: 2.67–351) on the first attempt, and to 1.7mm±1.9 (95%CI: 1.15-1.52) and 2.1mm±1.4 (95%CI: 0.87–1.15) on the second attempt. Concordance correlation improved from 0.43 (95% CI: 0.19–0.68) and 0.59 (95% CI: 0.44–0.79) using the standard protocol, to 0.88 (95%CI: 0.61–0.91) and 0.9 (95%CI: 0.56–0.92) using the novel protocol.

Conclusions

There is a difference in mean error and reliability between radiologically measured values for anterior prominence and values measured directly with present methods. The use of our novel protocol based on bony acetabular landmarks, significantly improves the accuracy of measurement. This protocol may improve reproducibility and the accuracy of this measurement and aid in the decision between tenotomy or revision of the acetabular component.

Level of evidence

III, in vitro study comparing diagnostic tools.

Le texte complet de cet article est disponible en PDF.

Keywords : Iliopsoas, Impingement, Anterior, Prominence, Acetabulum, Arthroplasty


Plan


Crown Copyright © 2019  Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 106 - N° 3

P. 563-568 - mai 2020 Retour au numéro
Article précédent Article précédent
  • Development of the French-Canadian Version of the Self-Administered Comorbidities Questionnaire (SCQ) in a hospital population undergoing hip or knee arthroplasty
  • Lissa Pacheco-Brousseau, Stéphane Poitras, Jacinthe Savard, Daniel Varin, Guy Moreau, Wadih Y. Matar, Paul Beaulé
| Article suivant Article suivant
  • Femoroacetabular impingement treatment using the arthroscopic extracapsular outside-in approach: Does capsular suture affect functional outcome?
  • Mathieu Thaunat, Saliou Sarr, Thanos Georgeokostas, Abdul Azeem, Colin G Murphy, Samih Kacem, Gilles Clowez, Timothy Roberts

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.