S'abonner

Hip resurfacing generates a more physiological gait than total hip replacement: A case-control study - 25/04/20

Doi : 10.1016/j.otsr.2019.12.020 
Cedric Maillot a, Edouard Auvinet a, Ciara Harman b, Justin Cobb a, Charles Rivière a, b,
a Laboratory Block, MSK Lab, Imperial college London, White City Campus, W12 0BZ London, United Kingdom 
b South West London Elective Orthopaedic Centre, Dorking road, KT18 7EG Epsom, United Kingdom 

Corresponding author at: Laboratory Block, MSK Lab, Imperial college London,White City Campus, W12 0BZ London, United Kingdom.Laboratory Block, MSK Lab, Imperial college London, White City CampusLondonW12 0BZUnited Kingdom

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Restoration of the constitutional joint anatomy after hip replacement favours physiological peri-articular soft-tissue tension and kinematics, and is likely to be functionally beneficial. Hip resurfacing (HR) and conventional total hip replacement (THR) are two different options for replacing degenerated hips, and are likely to result in different anatomical reconstruction. We initiated this study to investigate the differences in gait performance between these two prosthetic options, and aimed to answer the following questions: (1) does HR result in better restoration of the frontal hip anatomical parameters, (2) and generate a more physiological gait compared to THR? (3) Does the quality of the anatomical restoration after THR influence gait performance?

Hypotheses

Our hypothesis was that a better anatomical restoration using HR versus THR would produce more physiological (symmetric) gait.

Methods

We retrospectively reviewed 52 patients who had unilateral primary osteoarthritis successfully treated by replacement (40 THRs and 12 HRs). Hip anatomical parameters were measured on standing pelvic radiographs on both the prosthetic and the contralateral healthy hips. Patients undertook gait assessment under both normal and stress conditions at a mean follow-up of 14 months (7 to 16 months). Gait performances were compared between HR and THR, and the relationship between gait performances and quality of frontal anatomical restoration (estimated on radiograph) were assessed.

Results

Compared to the native contralateral side, the HR procedure tended to decrease all independent anatomical radiographic parameters with the exception of the vertical centre of rotation offset, whilst the THR procedure tended to increase them; the difference between HR and THR was only statistically significant for femoral offset and global horizontal offset (increased after THR while reduced after HR). Only 50% of THR and 25% of HR procedures closely anatomically (±15%) recreated both global horizontal offset and global vertical offset. Under normal conditions (normal walking speed and flat ramp), the gait was fairly symmetric for both the HR and the THR patients with a symmetry index of 0.62% and 3.14% respectively. At high walking speed (stress conditions), the symmetry index degraded for both groups, but the gait remained more symmetric in the HR group (2.09%), compared to the THR group (5.74%); nevertheless, the difference remained not statistically significant (p=0.159). We were unable to detect any significant relationship between gait performances and radiographically measured hip frontal anatomical parameters.

Discussion/conclusions

HR procedure is more consistent than conventional THR in generating a more physiological gait under stress conditions. Radiographic estimation of the quality of the frontal anatomical hip restoration is of poor value to predict gait performances of THR patients.

Level of evidence

III – retrospective case-control study with prospective data collection.

Le texte complet de cet article est disponible en PDF.

Keywords : Hip replacement, Hip resurfacing, Gait analysis, Symmetry index, Kinematic alignment


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 106 - N° 3

P. 527-534 - mai 2020 Retour au numéro
Article précédent Article précédent
  • Prospective randomized study using EBRA-FCA to compare bone fixation between cementless SL-PLUS Zweymüller versus SL-PLUS MIA femoral implants in primary total hip arthroplasty with clinical assessment at a minimum 5 years’ follow-up
  • Etienne Caron, Henri Migaud, Gilles Pasquier, Julien Girard, Sophie Putman
| Article suivant Article suivant
  • Is the economic and social cost of one-stage bilateral hip resurfacing lower than two-stage procedures? Retrospective case-control study of 260 hips
  • Antoine Hoestlandt, Julien Dartus, Cyril Delay, Pierre Martinot, Julien Girard

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.