S'abonner

Comparison of Holter With Zio Patch Electrocardiography Monitoring in Children - 10/02/20

Doi : 10.1016/j.amjcard.2019.11.028 
Meena Bolourchi, MD, Eric S. Silver, MD, David Muwanga, BS, Esteban Mendez, Leonardo Liberman, MD
 Department of Pediatrics, Division of Pediatric Cardiology, Columbia University, College of Physicians and Surgeons, New York, New York 

Corresponding author: Tel: (212) 342-0525; fax: (212) 342-5721.

Résumé

The standard for ambulatory arrhythmia detection in children is the Holter monitor. The Zio XT (Zio) patch has been FDA-approved for use in adults. However, its utility in children has not been directly compared with the Holter. We studied the ability to detect arrhythmias and patient comfort of the Zio versus the Holter in children. Patients <22 years old were prospectively enrolled to wear the Holter and Zio simultaneously for 48 hours at our institution. Detection of clinically significant arrhythmias was compared using McNemar's test. Wear-time and artifact time was compared using Wilcoxon sign test. Patient satisfaction ratings were analyzed with paired t tests. Two hundred patients (57% male) were included for analysis. The median age was 13.5 years (range 23 days to 21.7 years), and 40% had heart disease. The Zio and Holter had comparable median wear-times, 48.2 hours (interquartile range [IQR] 45.8 to 50.2]) versus 48.0 (48.0 to 48.0), respectively, p = 0.14, but the Zio had less artifact than the Holter, 2.8% (IQR 1.1 to 8.6) versus 5.6% (2.4 to 15.7), respectively, p <0.001. There was no difference in detection of clinically significant arrhythmias for the Zio versus the Holter (p = 0.23), however 75% of patients preferred the Zio over the Holter (p <0.001) due to lack of wires and the ability to shower. In conclusion, the Zio patch is as good as the Holter monitor in detection of clinically significant arrhythmias in children with less artifact. Patients/parents more often preferred the Zio over the Holter.

Le texte complet de cet article est disponible en PDF.

Plan


 Grant Support: All phases of this study were supported by Colin's Kids Grant (New York, NY, USA) and Matthew's Hearts of Hope Grant (New York, NY, USA). There was no involvement by Colin's Kids or Matthew's Hearts of Hope grants in the study design, data collection, analysis, or interpretation, or in writing of the report, or in the decision to submit the article for publication.


© 2019  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 125 - N° 5

P. 767-771 - mars 2020 Retour au numéro
Article précédent Article précédent
  • Usefulness of Preprocedural Left Ventricular End-Systolic Volume Index and Early Diastolic Mitral Annular Velocity in Predicting Improvement in Left Ventricular Ejection Fraction Following Atrial Fibrillation Ablation in Patients With Impaired Left Ventricular Systolic Function
  • Kyoichiro Yazaki, Koichiro Ejima, Miwa Kanai, Shohei Kataoka, Satoshi Higuchi, Daigo Yagishita, Morio Shoda, Nobuhisa Hagiwara
| Article suivant Article suivant
  • Prognostic Value of Serum Uric Acid in Hospitalized Heart Failure Patients With Preserved Ejection Fraction (from the Japanese Nationwide Multicenter Registry)
  • Yuta Kobayashi, Kazunori Omote, Toshiyuki Nagai, Kiwamu Kamiya, Takao Konishi, Takuma Sato, Yoshiya Kato, Hirokazu Komoriyama, Shingo Tsujinaga, Hiroyuki Iwano, Kazuhiro Yamamoto, Tsutomu Yoshikawa, Yoshihiko Saito, Toshihisa Anzai

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.