S'abonner

Effectiveness and Safety of Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis and Variable Ejection Fractions (<40%, 40%-49%, and >50%) - 25/01/20

Doi : 10.1016/j.amjcard.2019.10.059 
Ilan Merdler, MD, MHA 1, Itamar Loewenstein, MD 1, Aviram Hochstadt, MD, Samuel Morgan, BSc, Sivan Schwarzbard, MD, Ben Sadeh, MD, Yogev Peri, MD, Yacov Shacham, MD, Ariel Finkelstein, MD, Arie Steinvil, MD
 Department of Cardiology, Tel-Aviv Sourasky Medical Center affiliated to the Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel 

Corresponding author: Tel: +972-3-6973222; fax: +972-3-6973704.

Résumé

We evaluated the safety and efficacy of transcatheter aortic valve implantation (TAVI) in aortic stenosis patients with mid-range ejection fraction (ASmrEF) and compared it to aortic stenosis patients with reduced ejection fraction (ASrEF) and preserved ejection fraction (ASpEF). TAVI cases were stratified by baseline ejection fraction (ASrEF, ASmrEF, ASpEF) and compared for characteristics, procedural outcomes, and change in echocardiographic parameters at 1 year and mortality over a 5-year follow-up. The final study population included 708 patients who underwent TAVI. ASmrEF patients presented with improved EF at 1-year after procedure (49.0 ± 9.8 at 1 year vs 43.0 ± 2.5 at baseline, p <0.001) and showed improvements in left ventricular (LV) diameters (LV end-diastolic diameter: 50.4 ± 6.0 at 1 year vs 53.0 ± 5.5 at baseline and LV end-systolic diameter 34.7 ± 7.8 at 1 year vs 39.5 ± 5.9 at baseline, p <0.001 for both). LVEF improved for patients with ASrEF but not in ASpEF patients. LV diameters did not improve for patients in either group. Procedural safety and success rates were similar between all heart failure groups. Survival rates over a 5-year follow-up post-TAVI were not different between patients with ASmrEF, ASrEF, and ASpEF (ASrEF 78.4%, ASmrEF 81.9%, ASpEF 78.3%, p = 0.327). TAVI for patients with ASmrEF is safe and effective and results in marked improvement of LV function and structure.

Le texte complet de cet article est disponible en PDF.

Plan


 All authors take responsibility for all aspects of the reliability and freedom from bias of the data presented and the associated interpretation.


© 2019  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 125 - N° 4

P. 583-588 - février 2020 Retour au numéro
Article précédent Article précédent
  • Effect of Serum Albumin Levels in Patients With Heart Failure With Preserved Ejection Fraction (from the TOPCAT Trial)
  • Stuart B. Prenner, Anupam Kumar, Lei Zhao, Mary E. Cvijic, Michael Basso, Thomas Spires, Zhuyin Li, Melissa Yarde, Priyanka Bhattacharya, Payman Zamani, Jeremy Mazurek, Zhaoqing Wang, Dietmar Seiffert, David A. Gordon, Julio A. Chirinos
| Article suivant Article suivant
  • Comparison of Survival of Transfemoral Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement for Aortic Stenosis in Low-Risk Patients Without Coronary Artery Disease
  • Marko P.O. Virtanen, Juhani Airaksinen, Matti Niemelä, Teemu Laakso, Annastiina Husso, Maina P. Jalava, Tuomas Tauriainen, Pasi Maaranen, Eeva-Maija Kinnunen, Sebastian Dahlbacka, Stefano Rosato, Mikko Savontaus, Tatu Juvonen, Mika Laine, Timo Mäkikallio, Antti Valtola, Peter Raivio, Markku Eskola, Fausto Biancari

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.