S'abonner

Rupture des membranes à terme avant travail. Recommandations pour la pratique clinique du CNGOF — Méthodes de déclenchement - 02/01/20

Term Prelabor Rupture of Membranes: CNGOF Guidelines for Clinical Practice — Methods for Inducing Labor

Doi : 10.1016/j.gofs.2019.10.014 
A. Girault a, , b
a Service de gynécologie-obstétrique, maternité Port-Royal, université de Paris, DHU risques et grossesse, AP–HP, 123, boulevard de Port-Royal, 75014 Paris, France 
b Epidemiology and statistics research center/CRESS, Inserm, INRA, université de Paris, 75004 Paris, France 

Correspondance.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Objectifs

Évaluer les études comparant les méthodes de déclenchement entre elles et déterminer si l’une d’elles est supérieure aux autres pour le déclenchement des femmes ayant rompu les membranes à terme avant travail (RMTAT).

Méthodes

Consultation de la base de données MedLine, de la Cochrane Library et des recommandations des sociétés savantes françaises et étrangères.

Résultats

Les études incluses comparent des méthodes de déclenchement médicamenteuses : l’oxytocine (voie intraveineuse), la dinoprostone (gel vaginal, système de diffusion vaginal et gel intracervical) et le misoprostol (voie orale et vaginale) ; et une méthode de déclenchement mécanique : la sonde de Foley. Leurs critères de jugement principaux sont la durée du délai déclenchement–accouchement, le nombre d’accouchements dans les 12 ou 24 premières heures et le taux de césarienne. Le faible effectif des études comparant les méthodes médicamenteuses, ainsi que le faible nombre de complications rapportées, empêchent toute conclusion sur les critères secondaires : fièvre pendant le travail, taux d’infection intra-utérine, survenue d’une hyperstimulation utérine, et score d’Apgar<7 à 5min de vie. La durée du délai déclenchement–accouchement est réduite lors du déclenchement par misoprostol (oral et vaginal) versus dinoprostone (NP2) et est comparable lors du déclenchement par oxytocine versus sonde de Foley® (NP2). Les données comparant cette durée chez les femmes déclenchées par dinoprostone versus oxytocine et misoprostol versus oxytocine sont limitées ou contradictoires. Le taux de césarienne est comparable chez les femmes déclenchées par dinoprostone (gel) versus oxytocine (NP2), misoprostol (oral et vaginal) versus oxytocine (NP2), sonde de Foley® versus oxytocine (NP2), misoprostol versus dinoprostone (NP2) et misoprostol versus sonde de Foley® (NP2). Le taux d’accouchement dans les 24h après le déclenchement est équivalent chez les femmes déclenchées par misoprostol oral versus oxytocine (NP2) et sonde de Foley® versus oxytocine (NP2). Les données concernant ce taux sont limitées ou inexistantes concernant les comparaisons suivantes : dinoprostone versus oxytocine, misoprostol vaginal versus oxytocine, et misoprostol versus dinoprostone. Dans les cas particuliers de la femme nullipare et de la femme avec col défavorable, aucun moyen de déclenchement n’est supérieur à un autre (NP2). Les données sont insuffisantes pour éliminer un sur-risque d’infection intra-utérine lors de l’utilisation de la sonde de Foley.

Conclusions

Les données actuelles ne permettent pas d’établir la supériorité d’une méthode de déclenchement par rapport à une autre en termes d’efficacité, ni de complication pour le déclenchement des ruptures des membranes à terme avant travail. Toutes les méthodes médicamenteuses peuvent être utilisées pour le déclenchement des RMTAT (Grade B) mais cependant ces données sont insuffisantes pour éliminer un sur-risque d’infection intra-utérine lors de l’utilisation de la sonde de Foley®.

Le texte complet de cet article est disponible en PDF.

Abstract

Objectives

To assess the studies comparing induction methods in women with term prelabor rupture of the membranes and establish if one is superior to the others.

Methods

The MedLine database, the Cochrane Library and the recommendations from the French and foreign obstetrical societies or colleges have been consulted.

Results

The included studies compared medical induction methods: oxytocin (intravenous), dinoprostone (vaginal gel, pessary or intracervical gel), and misoprostol (oral or vaginal route); and a mechanical induction method: the Foley catheter. The primary outcome measures were: labor induction to delivery interval, number of women delivered within 12 or 24hours of initiation of induction and cesarean delivery rate. The small sample size of the included studies as well as the limited number of reported complications does not provide a reasonable basis for concluding on the secondary outcome measures: pyrexia, chorioamnionitis, uterine tachysystole, Apgar scores of<7 at 5minutes. Induction of labor with misoprostol (oral and vaginal) reduced the labor induction to delivery interval compared with dinoprostone (LE2). This interval was unchanged when comparing induction with oxytocin and Foley catheter (LE2). The data comparing this interval in women induced with dinoprostone versus oxytocin and misoprostol versus oxytocin is limited or inconsistent. The cesarean delivery rate was comparable in women induced with dinoprostone (vaginal gel) versus oxytocin (LE2), misoprostol (oral and vaginal route) versus oxytocin (LE2), Foley catheter versus oxytocin (LE2), misoprostol versus dinoprostone (LE2) and misoprostol versus Foley catheter (LE2). The number of women delivered within 24hours of initiation of induction was comparable when induced with oral misoprostol versus oxytocin (LE2) and Foley catheter versus oxytocin (LE2). There is a lack of data for this outcome when comparing dinoprostone versus oxytocin, vaginal misoprotsol versus oxytocin, and misoprostol (oral and vaginal) versus dinoprostone. No induction method is superior to another for nulliparous women or women with unfavorable cervix (LE2).

Conclusion

The superiority of an induction method, in terms of effectiveness or safety, could not be established with the current available data for women with term prelabor rupture of the membranes. An increased risk of chorioamnionitis due to induction using Foley catheter could not be ruled out by the available data. All medical methods are suitable for inducing women with term prelabor rupture of the membranes (Grade B).

Le texte complet de cet article est disponible en PDF.

Mots clés : Rupture prématurée des membranes à terme, Rupture des membranes à terme avant travail, Déclenchement

Keywords : Term prelabor rupture of the membranes, Induction


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 48 - N° 1

P. 48-58 - janvier 2020 Retour au numéro
Article précédent Article précédent
  • Rupture des membranes à terme avant travail. Recommandations pour la pratique clinique du CNGOF — Faut-il déclencher ?
  • J. Sibiude
| Article suivant Article suivant
  • Présentation du siège. Recommandations pour la pratique clinique du CNGOF — Introduction
  • É. Verspyck, T. Schmitz, P. Rozenberg, M.-V. Senat, L. Sentilhes

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.