Functional and Morphological Evaluation of Meibomian Glands in the Assessment of Meibomian Gland Dysfunction Subtype and Severity - 12/11/19

Doi : 10.1016/j.ajo.2019.09.005 
Jiaxin Xiao a, b, , Muhammed Yasin Adil a, b, Xiangjun Chen c, d, e, f, g, Øygunn A. Utheim c, Sten Ræder c, Kim Alexander Tønseth b, h, Neil S. Lagali d, i, Darlene A. Dartt j, Tor P. Utheim b, d, e, f, g, h, k
a Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway 
b Department of Medical Biochemistry, Oslo University Hospital, Oslo, Norway 
c The Norwegian Dry Eye Clinic, Oslo, Norway 
d Department of Ophthalmology, Sørlandet Hospital, Arendal, Norway 
e Department of Ophthalmology, Oslo University Hospital, Oslo, Norway 
f Institute of Clinical Dentistry/Department of Oral Biology, Faculty of Dentistry, University of Oslo, Oslo, Norway 
g Faculty of Health Sciences, National Centre for Optics, Vision and Eye Care, University College of Southeast Norway, Kongsberg, Norway 
h Department of Plastic and Reconstructive Surgery, Oslo University Hospital, Oslo, Norway 
i Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden 
j Schepens Eye Research Institute, Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts, USA 
k Department of Ophthalmology, Stavanger University Hospital, Stavanger, Norway 

Inquiries to Jiaxin Xiao, Freserveien 13, 0195 Oslo, NorwayFreserveien 13Oslo0195Norway
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 12 November 2019
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Purpose

To classify subtypes of meibomian gland dysfunction (MGD) and evaluate the dependency of dry eye signs, symptoms, and parameters on MGD subtype.

Design

Cross-sectional study. Study Population: the right eyes of 447 patients with MGD of various subtypes and 20 healthy volunteers.

Methods

Patients were divided into 4 subtypes of MGD based on meibum expression, meibum quality, and MG loss on meibography images (meibograde of 0–6). Subtypes were patients with high meibum delivery (hypersecretory and nonobvious MGD) and those with low meibum delivery (hyposecretory and obstructive MGD). Additional clinical tests included tear film break-up time (TFBUT), ocular staining, osmolarity, Schirmer I, blink interval timing and the Ocular Surface Disease Index (OSDI) questionnaire.

Results

A total of 78 eyes had hypersecretory MGD; 49 eyes had nonobvious MGD; 66 eyes had hyposecretory MGD; and 254 eyes had obstructive MGD. Increased tear film osmolarity and lower TFBUT were found in the low-delivery groups; hyposecretory (P = 0.006, P = 0.016) and obstructive MGD (P = 0.008, P = 0.006) relative to high-delivery MGD (hypersecretory and nonobvious groups, respectively). Worse ocular symptoms and ocular staining were also found in low-delivery MGD groups than the high delivery MGD groups (P < 0.01 and P < 0.006, respectively).

Conclusions

Patients with low-delivery MGD had worse dry eye parameters and ocular symptoms than those with high meibum delivery, indicating the pivotal role of meibum secretion in ocular surface health that should be targeted in MGD therapy. Furthermore, nonobvious MGD cannot be diagnosed using conventional dry eye tests and requires morphologic assessment of meibography images to confirm MG loss.

Le texte complet de cet article est disponible en PDF.

Plan


 See Accompanying Editorial/Article on page xxx.


© 2019  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.