S'abonner

Influence de la tomodensitométrie 2D ou 3D sur la reproductibilité inter et intraobservateur de la classification des fractures du pilon tibial et des recommandations de prise en charge - 07/11/19

Impact of two- and three-dimensional computed tomography use on intraobserver and interobserver reliabilities of pilon fracture classification and treatment recommendation

Doi : 10.1016/j.rcot.2019.08.004 
Seong-Eun Byun a, Wonchul Choi a, Youngrak Choi a, , Tae-Keun Ahn a, Hyung Kyung Kim b, Sangchul Yoon c, Jongwook Lee d, Dae-Sung Choi a
a Department of orthopaedic surgery, CHA Bundang Medical Center, CHA University, 59, Yatap-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Republic of Korea 
b Department of Pathology, Kyung-Hee University Hospital at Gangdong, Republic of Korea 
c Center for Global Health and Innovation, National Medical Center, Republic of Korea 
d Department of Applied Economics, University of Minnesota, USA 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 2
Iconographies 0
Vidéos 0
Autres 0

Abstract

Background

Two-dimensional (2-D) and three-dimensional (3-D) computed tomography (CT) have been increasingly used in various intra-articular fractures including pilon fracture. However, no study has investigated intraobserver and interobserver reliabilities of pilon fracture classification using 3-D CT images.

Hypothesis

(1) Intraobserver and interobserver agreements of fracture classifications and treatment recommendations will improve by using 2-D CT images compared to using plain radiographs only; (2) agreements will improve by adding 3-D CT images compared to adding 2-D CT images; and (3) agreements of orthopedic residents rather than specialists will be influenced more by imaging modality.

Materials and methods

Ten orthopedic specialists and 10 residents completed a survey to classify the fractures according to the Rüedi-Allgöwer and AO/OTA classifications and to select treatment options using 25 pilon fracture images. The survey was conducted using plain radiographs, with 2-D and 3-D CT images introduced 3 and 6 weeks later, respectively. Kappa coefficients were calculated to determine reliabilities.

Results

Intraobserver reliabilities for fracture classifications in specialists significantly improved by using 2-D images compared to using plain radiographs only. Addition of 3D-CT did not significantly improve intraobserver reliabilities compared to those with 2-D CT. Use of 2-D CT images significantly improved overall interobserver agreement of both classifications, with the improvement being greater for residents. Use of 3-D CT images did not improve the interobserver reliability of both classifications. Overall interobserver reliabilities for treatment recommendations did not significantly differ according to the imaging modality. However, interobserver agreement among residents significantly improved from slight agreement using radiographs only to fair agreement using 2-D CT images.

Discussion

Intraobserver and interobserver reliabilities of pilon fracture classification and treatment recommendations did not improve between using 3-D and 2-D CT. Using 2-D CT images improved the intraobserver and interobserver reliabilities of the fracture classifications in specialists and the interobserver reliabilities of the fracture classifications and the treatment recommendations in residents.

Level of evidence

IV, case control study.

Le texte complet de cet article est disponible en PDF.

Keywords : Pilon fracture, Intraobserver reliability, Interobserver reliability, AO classification, Rüedi-Allgöwer classification, 3D CT

Abbreviations : 2-D, 3-D, CT



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 105 - N° 7

P. 900-901 - novembre 2019 Retour au numéro
Article précédent Article précédent
  • Incidence et facteurs de risque du syndrome du Cyclope après reconstruction du ligament croisé antérieur : revue systématique
  • Thibaut Noailles, Antoine Chalopin, Mathieu Boissard, Ronny Lopes, Nicolas Bouguennec, Alexandre Hardy
| Article suivant Article suivant
  • Neurotomie sélective des branches du nerf sciatique à destinée des muscles ischio-jambiers : une étude anatomique
  • Maxime Bretonnier, Jean-Michel Lemée, Jean-Eric Berton, Xavier Morandi, Claire Haegelen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.