Accuracy, repeatability and reproducibility of a handheld three-dimensional facial imaging device: The Vectra H1 - 05/09/19

Doi : 10.1016/j.jormas.2019.03.012 
C. Savoldelli a, , G. Benat a , L. Castillo a , E. Chamorey b , J.-C. Lutz c
a Department of oral and maxillofacial surgery, head and neck institute, university hospital of Nice, 06000 Nice, France 
b Biostatistic department, centre Antoine-Lacassagne, 06000 Nice, France 
c Maxillo-facial and plastic surgery department, Strasbourg university hospital, 67000 Strasbourg, France 

Corresponding author at: University Hospital of Nice, head and neck institute, department of oral and maxillofacial surgery, 31, avenue de Valombrose, 06000 Nice, France.University Hospital of Nice, head and neck institute, department of oral and maxillofacial surgery31, avenue de ValombroseNice06000France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 6
Vidéos 0
Autres 0

Abstract

Introduction

Three-dimensional imaging of facial surfaces is a useful tool in different fields of cranio-facial, maxillo-facial and facial aesthetic surgery. Many devices that use several stereoscopic cameras are available but require a dedicated room. In contrast, the Vectra H-1 is a handheld device that can be used regardless of location but requires three consecutive acquisition and might therefore provide less accuracy. The aim of this study was to assess the accuracy, repeatability and reproducibility of the Vectra H1 device to validate its use in daily medical practice.

Material and methods

A comparative analysis of the Vectra H1 device and a digital calliper was performed based on 23 distances measured among 11 facial landmarks.

One operator repeated the procedure six times on a 24-year-old male volunteer to assess repeatability, and six operators performed the measurement procedure on a 22-year-old female volunteer to assess reproducibility. Repeatability, reproducibility and accuracy versus the distances measured were successively assessed by testing the correlations between the distances measured versus the coefficient of variation (CV) calculated for repeatability, reproducibility and accuracy.

Results

The CVs for all distances ranged from 0.34% to 1.53% and decreased linearly when distances measured increased, and this correlation was significant (P = 0.0026) for repeatability. The CVs for all distances ranged from 0.23% to 2.90% and decreased linearly as distances measured increased; there was a significant correlation (P = 0.00045) for reproducibility.

Conclusions

This study shows that the Vectra H1 provides an accurate linear assessment of clinical parameters and allows the accurate analysis of craniofacial morphology. Furthermore, this device costs less and requires less space than other multi-pod devices.

Le texte complet de cet article est disponible en PDF.

Abbreviations : 2D, 3D, CT, VAM, SD, M, CV, SYST_E, JUST

Keywords : Stereophotogrammetry, 3D facial imaging, Measurement error


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 120 - N° 4

P. 289-296 - septembre 2019 Retour au numéro
Article précédent Article précédent
  • Deep learning in medical image analysis: A third eye for doctors
  • A. Fourcade, R.H. Khonsari
| Article suivant Article suivant
  • Fluorescent indocyanine green angiography: Preliminary results in microsurgery monitoring
  • V. Moris, S. Cristofari, A. Stivala, B. Lehre, C. Gengler, V. Rabuel, A. Srouji, N. Zwetyenga, D. Guilier

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.