S'abonner

Durability of Retropubic Suburethral Sling Procedure and Predictors for Successful Treatment Outcome in Women With Stress Urinary Incontinence - 23/08/19

Doi : 10.1016/j.urology.2019.05.015 
Hsin-Ho Liu 1, Hann-Chorng Kuo 2,
1 Department of Urology, Taichung Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taichung, Taiwan 
2 Department of Urology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation and Tzu Chi University, Hualien, Taiwan 

Address correspondence to: Hann-Chorng Kuo, M.D., Department of Urology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, 707, Section 3, Chung-Yang Road, Hualien, Taiwan.Department of UrologyHualien Tzu Chi HospitalBuddhist Tzu Chi Medical Foundation707, Section 3, Chung-Yang RoadHualienTaiwan

Abstract

Objective

To investigate the long-term durability of retropubic suburethral sling procedure for female stress urinary incontinence (SUI) and to identify urodynamic factors that might predict long-term successful outcomes.

Materials and Methods

In total, 286 women who underwent a retropubic suburethral sling for SUI were enrolled in this retrospective survey. Most patients received uroflowmetry, postvoid residual volume study and standardized video urodynamic testing preoperatively and 6 months postoperatively in half of them. Surgical results, demographic characteristics, preoperative and postoperative urodynamic parameters, and postoperative clinical manifestation were retrospectively analyzed. Urodynamic parameters that predict a failure outcome were investigated.

Results

The median follow-up period was 10 years (4-29 years). The overall subjective cure rate was 80.8%. The success rates of the sling procedures at 3, 5, 10, 15, and 20 years were 89.2%, 87.7%, 78.8%, 68.6%, and 60.0%, respectively. Vaginal delivery and greater parity had negative influence on cure rate (P = .004 and .013, respectively). A significant interaction was detected from the baseline to 6 months between successes and failures for maximum flow rate (Qmax) (P = .007), voided volume (P = .020), and bladder outlet obstruction index (P = .001). Univariate analysis revealed significant decrease of Qmax, volume, and voiding efficiency; and increase of postvoid residual volume, detrusor pressure, and bladder outlet obstruction index in patients with successful outcome. However, multivariate logistic regression failed to find predictive factors for a failure suburethral sling procedure.

Conclusion

Retropubic suburethral sling has a durable long-term effect for SUI. Slightly increased bladder outlet resistance after retropubic suburethral sling might be helpful for achieving long-term dryness.

Le texte complet de cet article est disponible en PDF.

Plan


 Financial Disclosures: None.
 Conflict of Interest: None.
 IRB: TCGH 105-154-B.
 This study was approved by the Research Ethics Committee of the hospital. Informed consent was waived due to the retrospective data analysis in nature. All methods were performed in accordance with the relevant guidelines and regulations.


© 2019  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 131

P. 83-88 - septembre 2019 Retour au numéro
Article précédent Article précédent
  • A Prospective Study to Evaluate Efficacy Using the Nuro Percutaneous Tibial Neuromodulation System in Drug-Naïve Patients With Overactive Bladder Syndrome
  • Kathleen Kobashi, Victor Nitti, Eric Margolis, Peter Sand, Steven Siegel, Salil Khandwala, Diane Newman, Scott A. MacDiarmid, Fangyu Kan, Elizabeth Michaud
| Article suivant Article suivant
  • Synchronous Urothelial Bladder and Renal Malignancies. Case Report and Review of Urologic Cancers in Patients With Familial Rb Mutations
  • Gabriel Z. Leinwand, Jacob W. Greenberg, Andrew B. Sholl, L. Spencer Krane

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.