S'abonner

Video screen viewing and first intubation attempt success with standard geometry video laryngoscope use - 25/06/19

Doi : 10.1016/j.ajem.2018.10.018 
Kenneth W. Dodd, M.D. a, b, , Matthew E. Prekker, M.D., M.P.H. a, b, c , Aaron E. Robinson, M.D., M.P.H. a , Ryan Buckley, M.D., M.P.H. a, 1 , Robert F. Reardon, M.D. a, c , Brian E. Driver, M.D. a, c
a Department of Emergency Medicine, Hennepin County Medical Center, 701 Park Avenue, Minneapolis, MN 55415, United States of America 
b Division of Pulmonary and Critical Care Medicine, Hennepin County Medical Center, 701 Park Avenue, Minneapolis, MN 55415, United States of America 
c Department of Emergency Medicine, University of Minnesota Medical School, 717 Delaware Street SE, Suite 508, Minneapolis, MN 55414, United States of America 

Corresponding author at: Department of Emergency Medicine, Hennepin County Medical Center, 701 Park Avenue, Minneapolis, MN 55415, United States of America.Department of Emergency MedicineHennepin County Medical Center701 Park AvenueMinneapolisMN55415United States of America

Abstract

Study objectives

Direct laryngoscopy (DL) is the traditional approach for emergency intubation but video laryngoscopy (VL) is gaining popularity. Some studies have demonstrated higher first-attempt success with VL, particularly in difficult airways. In real-world settings, physicians choose whether or not to view the video screen when utilizing VL devices for tracheal intubation. Therefore, we sought to determine whether screen viewing is associated with higher intubation first-attempt success in clinical practice.

Methods

In this retrospective, observational investigation, we studied consecutive adult emergency department intubations at an urban, academic medical center during the calendar year 2013. Cases were identified from the electronic medical record and analyzed using standard video review methodology. We compared first-attempt success rates when standard geometry Macintosh VL was used, stratified by whether the screen was viewed or not.

Results

Of the 593 cases with videos available for review, 515 (87%) were performed with a standard geometry Macintosh video laryngoscope. First-attempt success was not significantly different when the screen was viewed (195/207; 94% [95%CI 91–97]) compared to when the screen was not viewed (284/301; 94% [95%CI 92–97]). The median first-attempt duration was longer when the screen was viewed compared to when the screen was not viewed (45 versus 33 s; median difference 12 s [95%CI 10–15 s]).

Conclusion

In this study of orotracheal intubations performed by emergency physicians with Macintosh-style VL, the first-attempt success rate was high. The success rate was similar whether or not the intubating physician chose to view the video screen.

Le texte complet de cet article est disponible en PDF.

Keywords : Intubation, Laryngoscopy, Video laryngoscopy


Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 37 - N° 7

P. 1336-1339 - juillet 2019 Retour au numéro
Article précédent Article précédent
  • Optimal CT protocol for the diagnosis of active bleeding in abdominal trauma patients
  • Se Jong Kim, Su Joa Ahn, Seung Joon Choi, Dae Hong Park, Hyung Sik Kim, Jeong Ho Kim
| Article suivant Article suivant
  • Initial evaluation and management of wide-complex tachycardia: A simplified and practical approach
  • Laszlo Littmann, Elizabeth G. Olson, Michael A. Gibbs

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.