S'abonner

Cationic and anionic unloaded polymeric nanocapsules: Toxicological evaluation in rats shows low toxicity - 16/06/19

Doi : 10.1016/j.biopha.2019.109014 
Muriel Pando Pereira a, Marcelo Gomes de Gomes a, Jessica Cristina Izoton a, Kelly Ayumi Nakama a, Renata Bem dos Santos a, Anne Suely Pinto Savall b, Juliana Bernera Ramalho b, Silvane Souza Roman c, Cristiane Luchese d, Francielli Weber Cibin b, Simone Pinton b, Sandra Elisa Haas a,
a Programa de Pós-Graduação em Ciências Farmacêuticas, Universidade Federal do Pampa, Campus Uruguaiana BR 472, Km 7, 97500-970, Uruguaiana, RS, Brazil 
b Programa de Pós-Graduação em Bioquímica, Universidade Federal do Pampa, UNIPAMPA, Uruguaiana, Brazil 
c Universidade Regional Integrada do Alto Uruguai e das Missões, Campus Erechim, Erechim, Brazil 
d Programa de Pós-Graduação em Bioquímica e Bioprospecção, Laboratório de Pesquisa em Farmacologia Bioquímica, Centro de Ciências Químicas, Farmacêuticas e de Alimentos, Universidade Federal de Pelotas, Pelotas, Brazil 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 3
Vidéos 0
Autres 0

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Highlights

Anionic and cationic NCs-surfaces did not cause alterations in body weight and weight of organs.
Anionic and cationic surfaces of NCs did not altered oxidative stress markers in organs.
Cationic surfaces of NCs increased hepatic transaminases (AST and ALT).
Chitosan surface presented antioxidant activity in kidney.

Le texte complet de cet article est disponible en PDF.

Abstract

The experimental design aiming at evaluating the performance of drugs nanoencapsulated involves inclusion of a formulation without drug (unloaded). This formulation has sometimes presented per se effect. In this sense, we sought to evaluate the toxicity of unloaded polymeric nanocapsules (NCs) with different surfaces (cationic and anionic) in male Wistar rats in male Wistar rats. The physicochemical characterization of NCs with different surfaces: polysorbate 80 (P80), polyethylene glycol (PEG), eudragit ®RS 100 (EUD) and chitosan (CS) was performed. Rats were treated with unloaded NCs (P80, PEG, EUD and CS surfaces) daily for 14 days per oral route. 24 h of last treatment, animals were euthanized and organs were removed and weighted. After, biochemical determinations were performed. In general, NCs-surfaces did not cause alterations in body weight, weight of organs and histopathological analysis. PEG-surface NCs did not generate hepatotoxicity. In investigation of lipid profile, the surface with P80 changed TC and HDL-C levels. Besides that, all NCs did not alter oxidative stress markers in organs studied (TBARS and Reactive Species) and CS-surface presented antioxidant activity in kidney. This study demonstrated that NCs-surfaces depending on their physicochemical characteristics had low or no toxicity.

Le texte complet de cet article est disponible en PDF.

Keywords : Surfaces, Nanocapsules, Nanotoxicology, Lipid-core


Plan


© 2019  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 116

Article 109014- août 2019 Retour au numéro
Article précédent Article précédent
  • Coupling the near-infrared fluorescent dye IR-780 with cabazitaxel makes renal cell carcinoma chemotherapy possible
  • Yu Zheng, Ting Lan, Di Wei, Geng Zhang, Guangdong Hou, Jiarui Yuan, Fei Yan, Fuli Wang, Ping Meng, Xiaojian Yang, Guo Chen, Zheng Zhu, Zifan Lu, Wei He, Jianlin Yuan
| Article suivant Article suivant
  • An edible fungi Pleurotus ostreatus inhibits adipogenesis via suppressing expression of PPAR γ and C/EBP α in 3T3-L1 cells: In vitro validation of gene knock out of RNAs in PPAR γ using CRISPR spcas9
  • Bindhu J, Arunava Das

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.