S'abonner

Distal femoral hemiepiphysiodesis with screws and suture versus 8-plate for the treatment of genu valgum in children - 29/05/19

Doi : 10.1016/j.otsr.2019.02.019 
Gino Martínez , Alejandro Gündel, Pablo Ruiz, Ismael Cañete, Felipe Hodgson
 Department of Traumatology and Orthopedics, Clinical Hospital of Pontificia Universidad Católica de Chile, Santiago, Chile 

Corresponding author. Pediatric Orthopedics, Pontificia Universidad Católica de Chile, School of Medicine, Orthopaedic Surgery, Diagonal Paraguay 362, Santiago de Chile, Chile.Pediatric Orthopedics, Pontificia Universidad Católica de Chile, School of Medicine, Orthopaedic Surgery, Diagonal Paraguay 362Chile

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

There are different techniques for gradual correction of angular deformities in lower limbs. The use of screws and non-absorbable filament have been described as an effective alternative for transitory hemiepiphysiodesis in pediatric population.

Hypothesis

In pediatric population with genu valgum there are no differences in outcome between hemiepiphysiodesis, using screws and non-absorbable filament (SNAF) versus 8-plate.

Methods

Retrospective evaluation, 44 knees in 22 patients younger than 15 years, with idiopathic genu valgum, were operated on. One group (20 knees) was operated on with 8-plate technique and another group (24 knees) was operated on with SNAF technique. Initial and final intermalleolar distance (IMD) and mechanical lateral distal femoral angle (mLDFA) were compared, registering complications for each group. Mann-Whitney test was used for statistics, with significance value <0.05.

Results

All patients achieved the expected mechanical axis correction. IMD and mLDFA significatively improved. There were no significant differences in magnitude and speed of correction when comparing the two techniques. Only one SNAF patient had a minor perioperative complication.

Discussion

This report compares postoperative results between SNAF and 8-plate technique for correction of angular deformities in lower limbs. In this series of patients, significant clinical and radiological changes were observed between the initial and final values using both techniques, with no significant differences between them. Our group proposes the SNAF technique as an efficient, simple and cost-effective alternative to the traditional 8-plate technique, for the treatment of idiopathic genu valgum in children.

Level of evidence

III, retrospective comparative study.

Le texte complet de cet article est disponible en PDF.

Keywords : Genu valgum, Child, Growth plate, Epiphysiodesis, Surgical procedures


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 105 - N° 4

P. 751-755 - juin 2019 Retour au numéro
Article précédent Article précédent
  • Anterior cruciate ligament tears in children: Management and growth disturbances. A survey of French Arthroscopy Society members
  • Gauthier Gracia, Camille Thévenin-Lemoine, Pierre Laumonerie, Jérôme Sales de Gauzy, Franck Accadbled, French Arthroscopy Society
| Article suivant Article suivant
  • Bone healing is achievable despite extensive wound dehiscence and wide plate and screws exposure in children
  • E. Melhem, W. Bayoud, I. Ghanem

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.