Synovial C-reactive protein features high negative predictive value but is not useful as a single diagnostic parameter in suspected periprosthetic joint infection (PJI) - 11/05/19

Doi : 10.1016/j.jinf.2019.04.003 
A. Plate a, , A. Anagnostopoulos a, J. Glanzmann a, L. Stadler a, L. Weigelt b, R. Sutter c, M. Kästli d, A.S. Zinkernagel a, P.O. Zingg b, Y. Achermann a
a Division of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich, University of Zurich, Raemistrasse 100, CH-8091 Zurich, Switzerland 
b Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland 
c Department of Radiology, Balgrist University Hospital, University of Zurich, Zurich, Switzerland 
d Zentrallabour Zurich, Zurich, Switzerland 

Corresponding author.

Highlights

Synovial fluid C-reactive protein has a high negative predictive value of 98%.
In periprosthetic joint infections it is significant elevated.
There is no additional advantage to the established MSIS criteria.

Le texte complet de cet article est disponible en PDF.

Abstract

Objectives

Synovial fluid C-reactive protein (syCRP) has been recently described as a new biomarker in preoperative diagnostics to identify periprosthetic joint infections (PJI). The aim of this study was to evaluate syCRP in a large cohort of patients with suspected PJI and to calculate the optimal cut-off to diagnose PJI.

Methods

Between September 2015 and June 2017, we prospectively included patients with suspected PJI, in which syCRP was additionally measured along with routine preoperative diagnostic serum and synovial biomarkers. We analysed the sensitivity and specificity of syCRP using receiver operating characteristic curves.

Results

We included 192 cases (hip n = 80, knee n = 91, shoulder n = 21) with a final diagnosis of PJI in 26 cases (14.0%). Combined for all joints, the syCRP values were significantly higher in the PJI group than in the no PJI group (median: 13.8 vs. 0 mg/l; p < 0.001). The optimal cut-off (Youden Index: 0.71) for the PJI diagnosis combined for all joints was at a syCRP value of 2.9 mg/l with a sensitivity of 88%, a specificity of 82%, and a negative predictive value of 98%.

Conclusions

SyCRP features high negative predictive value but is not useful as a single diagnostic parameter in suspected periprosthetic joint infection (PJI).

Le texte complet de cet article est disponible en PDF.

Keywords : Synovial fluid C-reactive protein (CRP), Periprosthetic joint infection (PJI), Sensitivity, Specificity, ROC analysis


Plan


© 2019  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 78 - N° 6

P. 439-444 - juin 2019 Retour au numéro
Article précédent Article précédent
  • Septic shock among patients with systemic lupus erythematosus: Short and long-term outcome. Analysis of a French nationwide database
  • Arthur Mageau, Karim Sacré, Anne Perozziello, Stéphane Ruckly, Claire Dupuis, Lila Bouadma, Thomas Papo, Jean-François Timsit
| Article suivant Article suivant
  • Antibiotic resistance gene reservoir in live poultry markets
  • Yanan Wang, Yongfei Hu, Jian Cao, Yuhai Bi, Na Lv, Fei Liu, Shihao Liang, Yi Shi, Xinan Jiao, George Fu Gao, Baoli Zhu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.