S'abonner

Evaluation of neutron dosimetry on pancreatic cancer phantom model for application of intraoperative boron neutron-capture therapy - 22/03/08

Doi : 10.1016/j.biopha.2006.12.008 
Hironobu Yanagie a, , Yosiyuki Sakurai b, Koichi Ogura c, Tooru Kobayashi b, Yoshitaka Furuya d, Hirotaka Sugiyama e, Hisao Kobayashi f, Koji Ono b, Keiichi Nakagawa g, Hiroyuki Takahashi h, Masaharu Nakazawa h, Masazumi Eriguchi a
a Research Center for Advanced Science and Technology, The University of Tokyo, Tokyo, Japan 
b Research Reactor Institute, Kyoto University, Osaka, Japan 
c College of Industrial Technology, Nihon University, Chiba, Japan 
d Department of Surgery, Teikyo University Ichihara Hospital, Chiba, Japan 
e Department of Microbiology, Nihon Medical University, Tokyo, Japan 
f Institute for Atomic Energy, Rikkyo University, Kanagawa, Japan 
g Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan 
h Department of Quantum Engineering and Systems Science, The University of Tokyo, Tokyo, Japan 

Corresponding author. Department of Intellectual Property, Incubation Project: Inhibition of Cancer Metastasis, Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8904, Japan. Tel.: +81 3 5452 5436; fax: +81 3 5452 5434.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 10
Iconographies 16
Vidéos 0
Autres 0

Abstract

Pancreatic cancer is one of the most difficult neoplasms to cure and there is a need for new combinated therapy. If sufficient boron compound can be targeted accurate to the tumour, Boron Neutron-Capture Therapy (BNCT) can be applied to pancreatic cancer. We administrated BNCT to a cancer with pancreatic cancer patient using intraoperative irradiation. In this study, we performed preliminary dosimetry of a phantom model of the abdominal cavity. The flux of 8>×107n/cm2/s (0.1 ratio) was 4.5cm in depth from the surface in the case of simple irradiation, and the field of thermal neutrons was spread as 13cm and 11.5cm were usage of Void and Void with LiF collimation, respectively in thermal (OO-0011) mode. In the case of epithermal (CO-0000) mode, epithermal and fast components are four times higher at the surface level. In the case of mixed beam (OO-0000) mode, thermal neutron flux was the same as thermal neutron mode at a depth of 10cm, but the gamma-ray component was two times higher than that of thermal neutron mode. With the use of Void and LiF collimation, thermal neutrons were selectively applied to the tumour combined with the CT-imaging of the cancer patient. This means that we could irradiate the tumour selectively and safely as possible, reducing the effects on neighboring healthy tissues. High resolution whole body dosimetry will be necessary to extend the application of BNCT to pancreatic cancer.

Le texte complet de cet article est disponible en PDF.

Keywords : Boron Neutron-Capture Therapy (BNCT), Pancreatic cancer, Intraoperative BNCT, Thermal neutron, Void, LiF collimation


Plan


© 2007  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 61 - N° 8

P. 505-514 - septembre 2007 Retour au numéro
Article précédent Article précédent
  • Trypanocidal activity of arsonoliposomes: Effect of vesicle lipid composition
  • Paraskevi Zagana, Pavlos Klepetsanis, Panayiotis V. Ioannou, Philippe M. Loiseau, S.G. Antimisiaris

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.