Eye injury from electrical weapon probes: Mechanisms and treatment - 02/03/19

Doi : 10.1016/j.ajem.2018.06.004 
Mark W. Kroll, PhD, FAIMBE a, g, , Mollie B. Ritter, PA, MS b, Eric A. Kennedy, PhD c, Nora K. Siegal, MD PhD d, Roman Shinder, MD d, Michael A. Brave, JD, MS e, Howard E. Williams, PhD f
a Biomedical Engineering, University of Minnesota, United States 
b Piedmont Health System, Atlanta, GA, United States 
c Biomedical Engineering, Bucknell University, Lewisburg, PA, United States 
d Department of Ophthalmology, SUNY Downstate Medical Center, Brooklyn, NY, United States 
e LAAW International, LLC, United States 
f School of Criminal Justice, Texas State University, San Marcos, TX, United States 
g California Polytechnical Institute, United States 

Corresponding author at: Box 23, Crystal Bay, MN 55323, United States.Box 23Crystal BayMN55323United States

Abstract

Purpose

While generally reducing morbidity and mortality, TASER® electrical weapons have risks associated with their usage, including burn injuries and head and cervical trauma associated with uncontrolled falls. The primary non-fatal complications appear to be significant eye injury but no analysis of the mechanisms or suggested treatments has been published.

Methods

We used a biomechanical model to predict the risk of eye injury as a function of distance from the weapon muzzle to the eye. We compared our model results to recently published epidemiological findings. We also describe the typical presentation and suggest treatment options.

Results

The globe rupture model predicted that a globe rupture can be expected (50% risk) when the eye is within 6 m of the muzzle and decreases rapidly beyond that. This critical distance is 9 m for lens and retinal damage which is approximately the range of the most common probe cartridges. Beyond 9 m, hyphema is expected along with a perforation by the dart portion of the probe. Our prediction of globe rupture out to 6 m (out of a typical range of 9 m) is consistent with the published risk of enucleation or unilateral blindness being 69 ± 18%, with an eye penetration.

Conclusions

Significant eye injury is expected from a penetration by an electrical weapon probe at close range. The risk decreases rapidly at extended distances from the muzzle. Not all penetrating globe injuries from electrical weapon probes will result in blindness.

Le texte complet de cet article est disponible en PDF.

Keywords : Blind, CEW, ECD, Electrical weapon, Eye injury, TASER


Plan


© 2018  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 37 - N° 3

P. 427-432 - mars 2019 Retour au numéro
Article précédent Article précédent
  • National unintentional carbon monoxide poisoning estimates using hospitalization and emergency department data
  • Dorothy Stearns, Kanta Sircar
| Article suivant Article suivant
  • The intracranial number of foreign bodies as a predictor of mortality after penetrating brain injury
  • Mustafa Bolatkale, Ahmet Cagdas Acara

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.