Optimization of insulin regimen and glucose outcomes with short-term real-time continuous glucose monitoring (RT-CGM) in type 1 diabetic children with sub-optimal glucose control on multiple daily injections: The pediatric DIACCOR study - 07/02/19
pages | 7 |
Iconographies | 1 |
Vidéos | 0 |
Autres | 0 |
Abstract |
Background |
The impact of 7-day real-time continuous glucose monitoring (RT-CGM) on type 1 diabetes (T1D) management remains unknown in youths with suboptimal control by multiple daily injections (MDI). The DIACCOR Study aimed to describe treatment decisions and glucose outcomes after a short-term RT-CGM sequence in real-life conditions.
Methods |
This French multicenter longitudinal observational study included T1D youths with HbA1c>7.5% or a history of severe hypoglycemia (SH) or recurrent documented hypoglycemia. A sensor was inserted at the study-inclusion visit, and one of three predefined treatment changes was proposed by the investigator within 7–15 days: INT=MDI intensification, CSII=switch to continuous insulin infusion, or ER=educational reinforcement with no change in insulin regimen and a 4-month follow-up visit (M4) was scheduled.
Results |
A total of 229 children (12.2±3.5 years old) were recruited by 74 pediatricians; 12.8% had a history of SH, 22.2% had recurrent hypoglycemia. Baseline HbA1c was 8.7±1.5% (>7.5% in 82.8%). Overall, 139 (79.4%), 19 (10.9%), and 17 patients (9.7%) were, respectively, included in the INT, CSII, and ER subgroups. At M4, the global incidence of SH and recurrent hypoglycemia dropped (3.4% vs. 12.8% and 6.0% vs. 22.2%, respectively) as well as the incidence of ketoacidosis (2.1% vs. 8.1%) or ketosis (6.9% vs. 11.4%). The HbA1c decrease was significant overall and in the INT subgroup (adjusted difference −0.29%, P=0.009). The satisfaction rate was≥93.0% among children.
Conclusion |
In a real-life setting, a 1-week RT-CGM can promote treatment optimization in youths with uncontrolled T1D resulting mostly in less acute events. CGM acceptance may improve with new-generation sensors.
Le texte complet de cet article est disponible en PDF.Keywords : Type 1 diabetes, Continuous glucose monitoring (CGM), Multiple daily injections (MDI), Continuous subcutaneous insulin infusion (CSII), Pediatrics, Hypoglycemia
Plan
Vol 26 - N° 2
P. 95-101 - février 2019 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.
Déjà abonné à cette revue ?