S'abonner

Contrast-Induced Nephropathy After Percutaneous Coronary Intervention for Chronic Total Occlusion Versus Non-Occlusive Coronary Artery Disease - 13/11/18

Doi : 10.1016/j.amjcard.2018.08.022 
Ozan M. Demir, MBBS, MRCP a, b, Francesca Lombardo, MD a, c, Enrico Poletti, MD a, Alessandra Laricchia, MD a, Alessandro Beneduce, MD c, Davide Maccagni, RT a, Massimo Slavich, MD c, Francesco Giannini, MD a, Mauro Carlino, MD a, Alberto Margonato, MD c, Alberto Cappelletti, MD c, Antonio Colombo, MD a, Lorenzo Azzalini, MD, PhD, MSc a,
a Interventional Cardiology Division, Cardio-Thoracic-Vascular Department, San Raffaele Scientific Institute, Milan, Italy 
b Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, London, United Kingdom 
c Cardiology Division, Cardio-Thoracic-Vascular Department, San Raffaele Scientific Institute, Milan, Italy 

Corresponding author: Tel: +390226437331, fax: +390226437339.

Résumé

Contrast volume is associated with the incidence of contrast-induced nephropathy (CIN), and CIN risk could be particularly high in chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Our aim was to evaluate the incidence of CIN in patients who underwent CTO versus non-CTO PCI. All PCIs performed at our institution from January 2012 to December 2016 were included in this study. CIN was defined as an increase of ≥0.3 mg/dl or ≥50% from baseline within 72 hours. Multivariable logistic regression analysis was performed to identify independent predictors of CIN. A total of 2,580 patients were included (n = 309 CTO PCI and n = 2271 non-CTO PCI). Estimated glomerular filtration rate was lower in the non-CTO group (73.9 ± 27.3 vs 77.1 ± 24.7 ml/min/1.73/m2, p = 0.05). Patients in the non-CTO PCI group presented more often with acute coronary syndrome (47% vs 15%, p < 0.001). Contrast volume (347 ± 159 vs 215 ± 107 ml, p < 0.001) and contrast-volume-to-creatinine-clearance ratio (4.7 ± 2.1 vs 3.2 ± 1.8, p < 0.001) were higher in the CTO group. There was no difference in CIN rates between CTO and non-CTO groups (9.4% vs 12.1%, p = 0.17). This was confirmed in a sensitivity analysis including only patients who underwent PCI in a stable clinical setting (7.7% vs 8.5%, p = 0.66). On multivariate analysis hypotension during/before PCI (odds ratio [OR] 2.86), acute coronary syndrome (OR 1.86), age (OR 1.54), female sex (OR 1.51), left ventricular ejection fraction (OR 0.64), diabetes mellitus (OR 1.49), and contrast volume (OR 1.17) were independent predictors of CIN, while CTO PCI was not. In conclusion, CTO PCI is associated with similar rates of CIN, compared with non-CTO PCI. These findings persisted on sensitivity and multivariable analyses.

Le texte complet de cet article est disponible en PDF.

Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 122 - N° 11

P. 1837-1842 - décembre 2018 Retour au numéro
Article précédent Article précédent
  • Impact of Chronic Kidney Disease on Utilization of Coronary Angiography and Percutaneous Coronary Intervention, and Their Outcomes in Patients With Non-ST Elevation Myocardial Infarction
  • Jeff Murray, Abilash Balmuri, Alok Saurav, Aiman Smer, Venkata Mahesh Alla
| Article suivant Article suivant
  • Meta-Analysis of Bleeding Risk Prediction Scores in Patients After Percutaneous Coronary Intervention on Dual Antiplatelet Therapy
  • Stephanie Q. Ko, Linda R. Valsdottir, Jordan B. Strom, Yu-Chen Cheng, Atsushi Hirayama, Po-Hong Liu, Naoki Yanagisawa, Hsuan Yen, Changyu Shen, Robert W. Yeh

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.