S'abonner

Ultrasound for identifying the cricothyroid membrane prior to the anticipated difficult airway - 15/10/18

Doi : 10.1016/j.ajem.2018.07.027 
Stephen Alerhand, MD
 Department of Emergency Medicine, Rutgers New Jersey Medical School, 150 Bergen Street; Newark, NJ 07103, USA 

Abstract

Background

Prior to the anticipated difficult airway, the emergency physician commonly palpates the neck to identify the presumed location of the cricothyroid membrane (CTM). In the event of a “cannot-intubate, cannot‑oxygenate” airway, precise CTM localization is vital to the success of a cricothyrotomy and hence, the patient's survival.

Objective

This narrative review will summarize the prospective studies evaluating CTM identification. It will demonstrate the inaccuracy of the classically used landmark palpation technique. It will then describe the use of ultrasound (US) as a superior tool for CTM identification, illustrate the technique itself, and propose its implementation in the pre-intubation checklist for the anticipated difficult airway.

Discussion

Evidence demonstrates that physicians are not sufficiently accurate in palpating the CTM in both cadavers and volunteers in a stable non-emergent setting. In preparing for a real-time intubation, this fine motor task would be more difficult to achieve. Moreover, this particular patient group may often exhibit difficult airway features. US has been demonstrated to be superior for locating the CTM than landmark palpation across body habitus, gender, and failed airway simulations. This technique carries a short learning curve even without prior airway US experience, along with a high retention rate. An illustrative tutorial is provided.

Conclusion

Emergency physicians may apply this US technique for CTM localization in preparation for an anticipated difficult airway. However, since this technique takes longer than landmark palpation, using US is not recommended once already in the midst of a failed airway situation.

Le texte complet de cet article est disponible en PDF.

Keywords : Cricothyroid membrane, Ultrasound, Point-of-care ultrasound, Airway, Cricothyrotomy


Plan


 Sources of Support: N/A


© 2018  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 36 - N° 11

P. 2078-2084 - novembre 2018 Retour au numéro
Article précédent Article précédent
  • Meningitis presenting as acute psychosis in the ED: Speciality collaboration and rethinking the generalizability to real-world practice
  • Hidetaka Tamune
| Article suivant Article suivant
  • Vapocoolant spray versus placebo spray/no treatment for reducing pain from intravenous cannulation: A meta-analysis of randomized controlled trials
  • Yun Zhu, Xue Peng, Shuang Wang, Wenyu Chen, Congcong Liu, Bingmei Guo, Lin Zhao, Yuanpeng Gao, Kefang Wang, Fenglan Lou

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.