S'abonner

Can three-dimensional pelvimetry using low-dose stereoradiography replace low-dose CT pelvimetry? - 17/09/18

Doi : 10.1016/j.diii.2018.02.008 
S. Aubry a, b, , P. Padoin a, Y. Petegnief c, C. Vidal d, D. Riethmuller e, E. Delabrousse b, f
a Department of Musculoskeletal Imaging, CHRU Besançon, 25000 Besançon, France 
b Nanomedecine Laboratory, INSERM EA4662, University of Franche-Comte, 25000 Besançon, France 
c Department of Nuclear Medicine, CHRU Besançon, 25000 Besançon, France 
d Clinical Investigation Center, Inserm CIT808, CHRU Besançon, 25000 Besançon, France 
e Department of Obstetrics and Gynecology, CHRU Besançon, 25000 Besançon, France 
f Department of Abdominal Imaging, CHRU Besançon, 25000 Besançon, France 

Corresponding author. Department of Musculoskeletal Imaging, CHRU Besançon, 25030 Besançon cedex, France.Department of Musculoskeletal Imaging, CHRU Besançon, 25030 Besançon cedex, France.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

To evaluate the reliability of pelvimetric measurements performed using stereoradiographic imaging (SRI), and to assess maternal and fetal radiation doses compared to low-dose computer tomography (CT) pelvimetry.

Materials and methods

Thirty-five pregnant women (mean age, 29.6±5.5 [SD] years; range: 20–41 years) were prospectively included. All women underwent simultaneous frontal and lateral low-dose SRI and low-dose CT examination of the pelvis. Pelvimetry measurements were obtained from both examinations and radiation doses obtained with the two techniques were compared.

Results

SRI-CT correlation (Pearson coefficient correlation [r]; mean bias [mb]) was strong for transverse inlet diameter (r=0.92; mb=−0.09cm), anteroposterior diameter of the pelvic inlet (r=0.92; mb = 0.47cm), maximal transverse diameter (r=0.9; mb=0.21cm), sacrum length (r=0.9; mb=0.09cm). Correlation was good. Correlation was good for the sacrum depth (r=0.75; mb=0.06cm) and Magnin's index (r=0.7; mb=0.5cm). Correlation was moderate for anteroposterior diameter of pelvic outlet (r=0.6; mb=0.52cm). The fetal dose was 13.1 times lower using SRI (87±26μGy) than CT (1140±220μGy, P<0.0001). The effective maternal dose was 3.1 times lower using SRI (97±21μSv) than CT (310±60μSv; P<0.0001).

Conclusion

Pelvic inlet measurements using SRI are reliable. Compared to CT pelvimetry, SRI leads to a significant decrease in fetal and maternal radiation doses. These findings should prompt physicians to use SRI as the first-line approach for pelvimetry.

Le texte complet de cet article est disponible en PDF.

Keywords : Pelvimetry, Computed tomography (CT), Low-dose stereoradiographic imaging, Radiation dose evaluation, Technology assessment


Plan


© 2018  Soci showét showé françaises de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 9

P. 569-576 - septembre 2018 Retour au numéro
Article précédent Article précédent
  • Lower extremity CT angiography at 80 kVp using iterative model reconstruction
  • B. Liu, S. Gao, Z. Chang, C. Wang, Z. Liu, J. Zheng
| Article suivant Article suivant
  • Comment on "Shear wave elastography safety in fetus: A quantitative health risk assessment"
  • N. Mottet, R. Ramanah

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.