L’estimation visuelle des pertes sanguines des étudiants infirmiers anesthésistes en post-partum immédiat est-elle fiable ? - 25/08/18

Are nurse students in anaesthesiology visual estimate of blood loss in the immediate postpartum period reliable?

Doi : 10.1016/j.anrea.2017.03.002 
Anne Debost-Legrand 1, , Inès Parayre 2, Olivier Rivière 3, Isabelle Genes 4, Martine Mouchet 4, Françoise Vendittelli 1, 2, 3, 5
1 Centre hospitalier universitaire de Clermont-Ferrand, pôle femme et enfant, 63100 Clermont-Ferrand, France 
2 École de sages-femmes, faculté de médecine et de pharmacie, 63001 Clermont-Ferrand, France 
3 Université Claude-Bernard Lyon 1 – Laennec, association des utilisateurs de dossiers informatises en pédiatrie, obstétrique et gynécologie (Audipog), 69372 Lyon, France 
4 Centre hospitalier universitaire de Clermont-Ferrand, École d’infirmières anesthésistes diplômées d’état, 63000 Clermont-Ferrand, France 
5 EA 4681, périnatalité, grossesse, environnement, pratiques médicales et développement (PEPRADE), Clermont université, université d’Auvergne, 63001 Clermont-Ferrand, France 

Anne Debost-Legrand, centre hospitalier universitaire de Clermont-Ferrand, pôle femme et enfant, place Lucie-et-Raymond-Aubrac, 63000 Clermont-Ferrand, France.Anne Debost-Legrand, centre hospitalier universitaire de Clermont-Ferrand, pôle femme et enfant, place Lucie-et-Raymond-AubracClermont-Ferrand63000France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 1
Vidéos 0
Autres 0

Résumé

Introduction

L’objectif principal de cette étude était d’évaluer la conformité des estimations visuelles des pertes. Les objectifs secondaires étaient d’étudier la concordance des mesures intra-observateurs et d’évaluer la conformité des estimations visuelles pour des valeurs seuils cliniquement pertinentes.

Méthode

Une étude transversale multicentrique a été réalisée auprès d’étudiants infirmiers anesthésistes. Le questionnaire comportait 8 photographies dupliquées, de 8 volumes de pertes sanguines factices (100, 150, 200, 300, 500, 850, 1000, 1500mL). Une mesure étalon de 50mL a accompagné chaque photographie. Sept modalités de réponses étaient proposées pour chaque photographie. Un test du χ2 et Kappa a été réalisé.

Résultats

Parmi les 28 écoles françaises d’infirmiers anesthésistes, 19 ont diffusé le questionnaire. Seuls les étudiants de 2e année ont participé à l’étude, soit 161 étudiants. Le pourcentage de participation a été de 45,2 % et 2576 estimations visuelles ont été recueillies. L’estimation a été conforme pour 31,3 % des réponses. Le degré d’accord des estimations visuelles concordantes (0,2κ0,4) était modéré pour les volumes de 500 et 1500mL. Pour les estimations visuelles concordantes et conformes (0,2κ0,5), il était modéré pour 1000mL. Le pourcentage de réponses conformes était significativement plus élevé pour des volumes300mL comparés aux volumes500mL (40,1 % vs 17,7 % ; p<0,0001) et pour des volumes300mL comparés aux volumes1000mL (40,1 % vs 27,0 % ; p<0,0001).

Conclusion

Malgré l’apport d’une aide visuelle, la conformité et la reproductibilité des estimations visuelles sont restées faibles.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

In France, postpartum haemorrhage (blood loss500mL in the first 24h postpartum) is the leading direct obstetric cause of maternal mortality. In French practice, PPH is mainly diagnosed by a quantitative assessment of blood loss, performed by subjective methods such as visual estimates. Various studies have concluded that visual estimates are vague, tend to underestimate blood loss, and thus to delay diagnosis of PPH. The principal objective of this study was to assess the accuracy of visual estimates of blood loss by nurse students in anaesthesiology. The secondary objectives were to study intraobserver agreement of these assessments, to assess the accuracy of visual estimates for threshold values.

Methods

A cross-sectional multicentre study was performed in all French nurse schools of anaesthesiology (n=28), 19 participated. Volunteer French nurse students in their second year (n=161) were recruited. The online questionnaire contained 16 photographs (8 different, each presented twice) of simulated volumes of blood loss (100, 150, 200, 300, 500, 850, 1000, and 1500mL). A 50-mL reference standard for calibration accompanied each photograph. Only one answer could be selected among the 7 choices offered for each photograph. Comparisons used χ2 and Kappa tests.

Results

The participation rate was 45.2% and 2576 visual estimates were collected. Estimates were accurate for 31.3% of the responses. The reproducibility rates for the visual estimates (0.2κ0.4) were moderate for 500 and 1500mL and the accurate visual estimates (0.2κ0.5) was moderate for 1000mL. The percentage of accurate responses was significantly higher for volumes300mL than for those ≥500mL (40.1% vs. 17.7%; P<0.0001) and those ≥1000mL (40.1% vs. 27.0%; P<0.0001).

Conclusion

Despite the help of a visual aid, both the accuracy and reproducibility of the visual estimates were low.

Le texte complet de cet article est disponible en PDF.

Mots clés : Hémorragie du post-partum, Mortalité maternelle, Analyse des pratiques professionnelles, Estimation des pertes sanguines

Keywords : Postpartum haemorrhage, Maternal mortality, Professional practices analysis, Estimation of blood loss


Plan


© 2017  Société française d’anesthésie et de réanimation (Sfar). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 4 - N° 5

P. 370-377 - septembre 2018 Retour au numéro
Article précédent Article précédent
  • Impact de la mise en place d’une permanence de soins infirmiers anesthésistes en secteur de naissance sur la qualité de l’anesthésie-réanimation et analgésie obstétricale
  • Elise Ranvier-Davelu, Laurence Reumaux, Benoit Tavernier, Pierre Richart, Anne-Sophie Ducloy-Bouthors
| Article suivant Article suivant
  • Modalités d’administration des vasopresseurs pour césarienne programmée sous rachianesthésie : état des connaissances et perspectives
  • Mathieu Bobet, Domitille Dereu, Nejla Essafi, Frédéric J. Mercier, Morgan Le Guen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.