S'abonner

Patient-Specific Virtual Simulation—A State of the Art Approach to Teach Renal Tumor Localization - 24/08/18

Doi : 10.1016/j.urology.2018.04.043 
Arun Rai a, , Jason M. Scovell a, b, , Ang Xu a, Adithya Balasubramanian a, Ryan Siller a, Taylor Kohn a, Young Moon a, Naveen Yadav a, Richard E. Link a, c,
a Scott Department of Urology, Houston, TX 
b Translational Biology and Molecular Medicine, Houston, TX 
c Dan L. Duncan Comprehensive Cancer Center, Baylor College of Medicine, Houston, TX 

Address correspondence to: Richard E. Link, M.D., Ph.D., Carlton-Smith Endowed Chair in Urologic Education, Associate Professor of Urology, Scott Department of Urology, Baylor College of Medicine, 7200 Cambridge, MC BCM380, A10.107, Houston, TX 77030.Carlton-Smith Endowed Chair in Urologic Education, Associate Professor of Urology, Scott Department of UrologyBaylor College of Medicine7200 Cambridge, MC BCM380, A10.107HoustonTX77030
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 24 August 2018

Abstract

OBJECTIVE

To test whether a novel visuospatial testing platform improves trainee ability to convert two-dimensional to three-dimensional (3D) space.

METHODS

Medical students were recruited from Baylor College of Medicine and McGovern Medical School (Houston, TX). We 3D reconstructed 3 partial nephrectomy cases using a novel, rapid, and highly accurate edge-detection algorithm. Patient-specific reconstructions were imported into the dV-Trainer (Mimics Technologies, Seattle, WA) as well as used to generate custom 3D printed physical models. Tumor location was altered digitally to generate 9 physical models for each case, 1 with the correct tumor location and 8 with sham locations. Subjects were randomized 1:1 into the dV-Trainer (intervention) and No-dV-Trainer (control) groups. Each subject completed the following steps: (1) visualization of computed-tomographic images, (2) visualization of the reconstructed kidney and tumor in the dV-Trainer (intervention group only), and (3) selection of the correct tumor location on the 3D printed models (primary outcome). Normalized distances from the correct tumor location were quantified and compared between groups.

RESULTS

A total of 100 subjects were randomized for this study. dV-Trainer use significantly improved subjects ability to localize tumor position (tumor localization score: 0.24 vs 0.38, P < .001). However, subjects in the No-dV-Trainer group more accurately assigned R.E.N.A.L. scores.

CONCLUSION

Even brief exposure to interactive patient-specific renal tumor models improves a novice's ability to localize tumor location. Virtual reality simulation prior to surgery could benefit trainees learning to localize renal masses for minimally invasive partial nephrectomy.

Le texte complet de cet article est disponible en PDF.

Plan


 Financial Disclosure: Research reported in this publication was supported by the National Institute of General Medical Sciences of the National Institutes of Health under Award Number T32GM088129 as well as the loan of the dV-Trainer simulator platform from Mimics Technologies, Inc. (Seattle, WA). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health or Mimics Technologies.
 The authors declare no conflict of interest.


© 2018  Elsevier Ltd. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.