S'abonner

Interleukin-6 as a diagnostic marker for infection in critically ill patients: A systematic review and meta-analysis - 07/08/18

Doi : 10.1016/j.ajem.2018.05.040 
Shinya Iwase, MD a, Taka-aki Nakada, MD, PhD a, , Noriyuki Hattori, MD, PhD a, Waka Takahashi, MD, PhD a, Nozomi Takahashi, MD a, Tuerxun Aizimu, MEng b, Masahiro Yoshida, MD, PhD c, Toshio Morizane, MD, PhD d, Shigeto Oda, MD, PhD a
a Chiba University Graduate School of Medicine, Department of Emergency and Critical Care Medicine, 1-8-1 Inohana, Chuo, Chiba 260-8677, Japan 
b Center for Frontier Medical Engineering, Chiba University, Chiba, Japan 
c Department of Hemodialysis and Surgery, Chemotherapy Research Institute, Kaken Hospital, Chiba, Japan 
d Japan Council for Quality Health Care, Tokyo, Japan 

Corresponding author at: Chiba University Graduate School of Medicine, Department of Emergency and Critical Care Medicine, 1-8-1 Inohana, Chuo, Chiba 260-8677, Japan.Chiba University Graduate School of MedicineDepartment of Emergency and Critical Care Medicine1-8-1 InohanaChuoChiba260-8677Japan
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 07 August 2018
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

The ability of blood levels of interleukin (IL)-6 to differentiate between infection and non-infection in critically ill patients with suspected infection is unclear. We assessed the diagnostic accuracy of serum IL-6 levels for the diagnosis of infection in critically ill patients.

Methods

We systematically searched the PubMed, MEDLINE, Cochrane Resister of Controlled Trials, Cochrane Database of Systematic Reviews, CINAHL, and Igaku Chuo Zasshi databases for studies published from 1986 to August 2016 that evaluated the accuracy of IL-6 levels for the diagnosis of infection. We constructed 2 × 2 tables and calculated summary estimates of sensitivity and specificity using a bivariate random-effects model.

Results

The literature search identified 775 articles, six of which with a total of 527 patients were included according to the predefined criteria. The pooled sensitivity, specificity, and diagnostic odds ratio were 0.73 (95% confidence interval [CI], 0.61–0.82), 0.76 (95% CI, 0.61–0.87), and 2.31 (95% CI, 1.20–3.48), respectively. The area under the curve (AUC) of the summary receiver operator characteristic (SROC) curve was 0.81 (95% CI, 0.78–0.85). In the secondary analysis of two studies with a total of 263 adult critically ill patients with organ dysfunction, the pooled sensitivity, specificity, and diagnostic odds ratio were 0.81 (95% CI, 0.75–0.86), 0.77 (95% CI, 0.67–0.84), and 2.87 (95% CI 2.15–3.60), respectively.

Conclusions

Blood levels of IL-6 have a moderate diagnostic value and a potential clinical utility to differentiate infection in critically ill patients with suspected infection.

Le texte complet de cet article est disponible en PDF.

Keywords : Diagnosis, Biomarker, Critically ill patients, Sepsis, Septic shock, Organ dysfunction


Plan


© 2018  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.