The optimal conditions of therapeutic ultrasound on muscle stiffness of medial gastrocnemius muscle in human: A shear-wave elastography study - 15/07/18

Doi : 10.1016/j.rehab.2018.05.1104 
K. Morishita 1, 2, , S. Nishishita 2, 3, 4, M. Nakamura 5, J. Saeki 2, M. Yagi 2, T. Tsuboyama 2, N. Ichihashi 2
1 Josai International University, Physical Therapy, Togane, Japan 
2 Kyoto University, Graduate School of Medicine, Kyoto, Japan 
3 Tokuyukai Medical Corporation, Institute of Rehabilitation Science, Osaka, Japan 
4 Tokuyukai Medical Corporation, Kansai Rehabilitation Hospital, Osaka, Japan 
5 Niigata University of Health and Welfare, Institute for Human Movement and Medical Sciences, Niigata, Japan 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction/Background

Therapeutic ultrasound (TU) is most widely used as biophysical agents to treat contracture in orthopedics rehabilitation. Its effect is to increase range of motion by increasing tissue extensibility. However, no studies have reported the effect of TU on human muscle stiffness (MS). Also, the optimal conditions including frequency, intensity, and duty cycle of TU remain unclear. This study aimed to clarify the optimal TU conditions on MS using ultrasonic shear-wave elastography (SWE).

Material and method

This study was a randomized cross-over trial. All of the following TU conditions were applied on ten healthy males (mean±SD, age 25±2.9 y.o., height 171.2±4.7cm, weight 63.1±5.1kg); frequency (1 and 3MHz), intensity (continued mode: spatial average-temporal average (SATA) intensity of 0.5, 1.0, 1.5, and 2.0W/cm2; pulsed mode: 1.0, 2.0, and 3.0W/cm2 with 50% duty cycle (i.e., 0.5, 1.0, and 1.5W/cm2 SATA)) for 10minutes. Outcome was the change rate of MS in medial gastrocnemius (MG) muscle by using SWE. Statistical analysis was performed using one-way analysis of variance followed by Bonferroni post-hoc test.

Results

MS showed significant differences between the different frequency, intensity, and duty cycle. MS significantly decreased with 1.0, 1.5, and 2.0W/cm2 SATA than 0.5W/cm2 SATA at continued mode, and with 1.0, and 1.5W/cm2 SATA than 0.5W/cm2 SATA at pulsed mode at both 1MHz and 3MHz. There was no significant difference in MS between the above five SATA intensities, i.e., 1.0, 1.5, 2.0W/cm2 SATA at continued mode and 1.0, 1.5W/cm2 SATA at pulsed mode.

Conclusion

The optimal conditions of TU to decrease MS in MG were over 1.0W/cm2 SATA of intensity for both continued mode and pulsed mode at both 1MHz and 3MHz of frequency.

Le texte complet de cet article est disponible en PDF.

Keywords : Therapeutic ultrasound, Muscle stiffness, Shear-wave elastography


Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 61 - N° S

P. e473 - juillet 2018 Retour au numéro
Article précédent Article précédent
  • 3D laser scanner sensor for upper limb volume measurement in breast cancer related lymphedema: Preliminary results of a reproducibility and reliability study
  • M. Invernizzi, L. Lippi, S. Pasqua, A. Galetto, F. Gimigliano, N. Fusco, A. de Sire, C. Cisari
| Article suivant Article suivant
  • Temperature changes in bone by therapeutic ultrasound: An experimental setup with phantoms and a bovine ex vivo sample
  • D.B. Novaes, C.B. Santos, E.S. Lucena, E. Butterworth, W.C.A. Pereira, C.B. Machado

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.