S'abonner

Mechanical properties of muscles around shoulder in breast cancer patients: Intra- and inter-reliability and symmetry using MyotonPRO - 15/07/18

Doi : 10.1016/j.rehab.2018.05.1061 
S.Y. An , S.M. Yeo, I.Y. Cheong, J.H. Hwang
 Samsung Medical Center, Physical and Rehabilitation Medicine, Seoul, Republic of Korea 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction/Background

Treatment related shoulder dysfunction and anterior chest wall stiffness is common in breast cancer patients. Objective information of muscle properties can be useful for evaluating these problems and the effect of intervention. Recently MyotonPRO has been used to measure muscle properties such as stiffness, tone and elasticity. Our study aimed to assess mechanical properties and symmetry of muscles around shoulder and to investigate the inter- and intra-rater reliability of parameters measured by MyotonPRO in breast cancer patients.

Material and method

Twenty-two breast cancer patients who underwent mastectomy were studied. Frequency (tone, Hz), Stiffness (N/m) and Decrement (elasticity) were measured in both Pectoralis major (PM), Sternocleidomastoid (SMC) and Upper trapezius (UT). Rater 1 measured two sets with a time interval of 30minutes in order to confirm intra-rater reliability. Rater 2 measured one set at the time interval. After the each measurement, the markings are completely erased so as to not influence the subsequent testing session. A paired t-test was used to compare muscle properties between affected side and unaffected side. Reliability was assessed using intra-class correlation coefficients (ICCs) and Bland and Altman analysis.

Results

Intra-rater reliability was excellent (ICC>0.75, 0.85–0.98) in all parameters for two sets of repeated measurements from the PM, SCM and UT in affected and unaffected upper limb in breast cancer patients. Inter-rater reliability was fair to excellent in all parameters except the unaffected PM elasticity (ICC=0.34). Significant differences in all parameters were observed in the affected side PM and the unaffected side PM. In both SCM and UT, there was no significant difference between all the parameters.

Conclusion

Our findings indicate that MyotonPRO is a feasible tool to quantify PM stiffness and tone in breast cancer patients. Studies assessing the changes in PM muscle properties caused by pathology or treatments are needed.

Le texte complet de cet article est disponible en PDF.

Keywords : Breast cancer, Muscle tone, Reliability


Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 61 - N° S

P. e455 - juillet 2018 Retour au numéro
Article précédent Article précédent
  • Trunk muscle strength and endurance assessed by two methods in the isokinetic dynamometer for able-bodied and post-stroke hemiparesis people
  • M. Rabelo, E. Fachin-Martins
| Article suivant Article suivant
  • What is the best set of markers for facial movements recognition?
  • N. Dagnes, K. Ben-Mansour, F. Marcolin, F. Marin, F.R. Sarhan, S. Dakpé, E. Vezzetti

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.