S'abonner

Criterion validity of wearable sensors in lower limb joint angle estimation: A systematic review - 15/07/18

Doi : 10.1016/j.rehab.2018.05.1027 
I. Poitras , M. Bielmann, C. Mercier, L.J. Bouyer, J.S. Roy
 Laval University, Rehabilitation, Quebec, Canada 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction/Background

Motion capture systems are extensively used to measure human joint kinematics. These systems, however, lack portability and can only be used in laboratory settings. Recently, portable and wireless systems, such as inertial measurement units (IMU), have been developed and are seen as an alternative to quantify human movement outside of the laboratory. Several studies have established their psychometric properties. However, the variety of systems used and joints evaluated make it difficult to conclude on the validity of the different systems available. The aim of this systematic review is to determine the criterion validity of IMUs for the evaluation of lower limb kinematics when compared to motion capture systems.

Material and method

Five different databases were screened (Pubmed, Cinhal, Embase, Ergonomic abstract and Compendex). Included articles had to report on criterion validity of IMUs (vs. motion capture systems) of at least one joint in healthy adults. Only articles published after 2005 were considered. Pairs of raters conducted data extraction and critical appraisal using structured tools, and consensus had to be reached.

Results

A total of ten articles was included. Quality ratings of 30% of the studies reviewed were characterized as high, and 70% as moderated (interrater reliability: ICC=0.7). Knee and trunk movements showed moderate to good criterion validity, while hip and ankle movements were characterized as having poor to good validity.

Conclusion

IMU systems are valid to evaluate knee and trunk kinematics. For the hip and ankle, however, the validity varies according to movement studied. The measurement of hip flexion/extension, abduction/adduction and ankle plantar flexion/dorsiflexion with IMU can be considered as valid. For ankle inversion/eversion and hip internal/external rotation, the validity is poor. More studies are therefore needed to optimize the use of IMU for these movements (e.g. different calibration or biomechanical models).

Le texte complet de cet article est disponible en PDF.

Keywords : Validation, Range of motion, Inertial measurement unit


Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 61 - N° S

P. e441-e442 - juillet 2018 Retour au numéro
Article précédent Article précédent
  • Does muscle output function decrease following 12-hour immobilization period?
  • T. Inada, F. Kaneko, S. Koyama, J. Maruyama, J. Shindo
| Article suivant Article suivant
  • Forced use of the paretic leg induced by repeated exposure to constraint force applied to the non-paretic leg of individuals post-stroke during walking
  • M. Wu, C.J. Hsu, J. Kim

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.