S'abonner

Assessment of arterial occlusion pressure using pulse oximetry: A validation study - 15/07/18

Doi : 10.1016/j.rehab.2018.05.930 
Z. Zeng 1, 2, , C. Centner 1,  Gollhofer 1, D. König 1
1 University of Freiburg, Department of Sport and Sport Science, Freiburg, Germany 
2 Chengdu Sport University, School of Sport Medicine and Health, Chengdu, China 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Introduction/Background

Blood-flow-restriction (BFR) training is recently progressively applied in functional training settings. The optimal cuff pressure during BFR exercise, current literature recommends using percentages of each individual's arterial occlusion pressure (AOP). Most frequently, blood flow is determined by Doppler ultrasound (DU) techniques. Despite its high accuracy, the practicability of this gold standard is limited and time-consuming. An alternative solution to assess blood volume changes and pulse is pulse oximetry (PO). It was hypothesized that measurement of AOP could simplify the determination of cuff pressure during BFR training. Therefore, the main purpose of this study was to evaluate the accuracy of the PO for measuring the AOP compared to the current gold standard DU.

Material and method

Thirty-five subjects (27.7±2.9 years) were enrolled in the study. Participants were positioned in a supine position and a 12-cm-wide cuff was applied in a counterbalanced order at the most proximal portion of the right upper and lower limb. The cuff pressure was then successively increased until the systolic pulse wave was no longer detected by DU and PO, respectively.

Results

The results show that the mean values of AOP were 145.7±19.1mmHg and 144.0±26.4mmHg for the upper limbs, 191.5±24.1mmHg and 174.5±28.3mmHg for the lower limbs tested by DU and PO respectively (Fig. 1). Significant differences (paired t-test) between the two methods were revealed for the lower limbs (P=0.000) but not for the upper limbs (P=0.621).

Conclusion

Our results indicate that, compared with the gold standard DU, the PO method has statistically acceptable accuracy when measuring AOP in upper limbs. However, in lower extremities the PO significantly underestimates the actual AOP. This must be considered when implementing PO as a method for determining cuff pressure for BFR exercise.

Le texte complet de cet article est disponible en PDF.

Keywords : Blood-flow-restriction training, Arterial occlusion pressure, Pulse oximetry


Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 61 - N° S

P. e398 - juillet 2018 Retour au numéro
Article précédent Article précédent
  • Hip motor control training did not improve muscle performance during jump landing in young dancers with recent ankle-foot injury
  • Y.F. Shih, C.T. Liu
| Article suivant Article suivant
  • Non-uniform deformation in Achilles tendon is not influenced by a change in knee angle or level of force production during isometric contractions
  • S. Bogaerts, C. De Brito Carvalho, De Groef, P. Suetens, K. Peers

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.