S'abonner

Detection and characterization of focal liver lesions with ultra-low dose computed tomography in neoplastic patients - 09/05/18

Doi : 10.1016/j.diii.2017.11.003 
A. Larbi , C. Orliac, J. Frandon, F. Pereira, A. Ruyer, J. Goupil, F. Macri, J.P. Beregi, J. Greffier
 Department of radiology, CHU de Nîmes, EA2415, MIG Nimes, place du Professeur-Robert-Debré, 30900 Nîmes, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

The purpose of this study was to evaluate and compare the diagnostic accuracy of ultra-low dose (ULD) computed tomography (CT) with that of standard dose (STD) CT in the detection and characterization of focal liver lesions in neoplastic patients.

Materials and methods

A total of 177 neoplastic patients who underwent two abdominopelvic CT examinations (one with STD and one with ULD protocol) for suspected focal liver lesions were included. There were 103 men and 74 women with a mean age of 64.6±14.4 (SD) (range: 19–93 years). Raw data images were reconstructed with iterative reconstruction. Dose length product (DLP) and effective dose for both protocols were compared. Images were independently evaluated by two radiologists for image-quality, diagnostic quality, and confidence level.

Results

DLP for STD and ULD were respectively 215.4±92.0 (SD) mGy·cm (range: 76–599mGy·cm) and 90.7±37.2 (SD) mGy·cm (range: 32–254mGy·cm). Effective dose for STD and ULD CT were 3.2±1.4 (SD) mSv (range: 1.1–9.0mSv) and 1.4±0.6 (SD) mSv (range: 0.5 to 3.8mSv). A significant 58% dose reduction was found between the two protocols (P<0.05). Noise, signal-to-noise ratio and contrast-to-noise ratio were higher with the ULD protocol compared to the STD protocol. No differences in subjective image quality were found between the two protocols. STD CT revealed focal liver lesions in 80 patients and ULD CT in 70 patients (P<0.05). ULD protocol resulted in a sensitivity of 83.8% and a specificity of 96.9% for the diagnosis of focal liver lesions although it was not able to characterize them properly (Se 62.5%).

Conclusion

STD CT helps detect and characterize focal liver lesions. ULD CT offers good performance to detect focal liver lesions but with lower performances for lesion characterization.

Le texte complet de cet article est disponible en PDF.

Keywords : Oncology, Focal liver lesion, Computed tomography (CT), Iterative reconstruction, Lesion detection

Abbreviations : BMI, CNR, CI, CT, CTDIvol, DLP, DRL, E, HU, IR, κ, mAseff, MRI, R, ROI, SAFIRE, Se, SNR, Sp, STD, ULD


Plan


© 2017  Editions françaises de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 5

P. 311-320 - mai 2018 Retour au numéro
Article précédent Article précédent
  • Role of diffusion-weighted MR imaging in predicting the grade of nonfunctional pancreatic neuroendocrine tumors
  • F. Kulali, A. Semiz-Oysu, M. Demir, M. Segmen-Yilmaz, Y. Bukte
| Article suivant Article suivant
  • Assessment of patient's peak skin dose during abdominopelvic embolization using radiochromic (Gafchromic) films
  • J. Greffier, J. Goupil, A. Larbi, X. Stefanovic, F. Pereira, G. Moliner, S. Ovtchinnikoff, J.P. Beregi, J. Frandon

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.