S'abonner

Validation of the (Troponin-only) Manchester ACS decision aid with a contemporary cardiac troponin I assay - 19/04/18

Doi : 10.1016/j.ajem.2017.09.032 
Patricia Va Den Berg a, Gillian Burrows b, Philip Lewis b, Simon Carley c, d, Richard Body c, d, e,
a Maastricht University, Faculty of Health, Medicine & Life Sciences Maastricht University, Universiteitssingel, Maastricht, The Netherlands 
b Stockport NHS Foundation Trust, Poplar Grove, Stockport, United Kingdom 
c Central Manchester University Hospitals NHS Foundation Trust, Oxford Road, Manchester M13 9WL, United Kingdom 
d Manchester Metropolitan University, United Kingdom 
e The University of Manchester, Manchester Academic Health Science Centre, Oxford Road, Manchester M13 9PL, United Kingdom 

Corresponding author at: Emergency Department, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL, United Kingdom.Emergency DepartmentManchester Royal InfirmaryOxford RoadManchesterM13 9WLUnited Kingdom

Abstract

Objectives

The Manchester Acute Coronary Syndromes (MACS) decision aid can ‘rules in’ and ‘rule out’ acute coronary syndromes (ACS) by combining a patient's symptoms with the results of a single blood test taken at the time of arrival in the Emergency Department (ED). The original model (MACS) included two biomarkers: high sensitivity cardiac troponin T (hs-cTnT) and heart-type fatty acid binding protein (h-FABP). A refined model without h-FABP was found to have comparable sensitivity but greater specificity. We sought to validate MACS and T-MACS using the contemporary Siemens Advia Centaur cardiac troponin I assay to increase usability in practice.

Methods

This is a secondary analysis from prospective diagnostic cohort study at Stepping Hill Hospital, United Kingdom. Patients presenting with chest pain of suspected cardiac nature warranting rule out for ACS were included. All patients underwent hs-cTnT testing at least 12h after peak symptoms. The primary outcome was a diagnosis of ACS, defined as either prevalent acute myocardial infarction (AMI) or incident major adverse cardiac events (death, AMI or coronary revascularization) within 30days.

Results

Of 405 included patients, 76 (18.8%) had ACS. MACS and T-MACS had similar C-statistics (0.94 for each, p=0.36) and sensitivity (difference 1.3%, 95% CI −1.3 to 3.9%, p=1.00) but T-MACS had significantly greater specificity (difference 16.7%, 95% CI 14.6–18.9%, p<0.0001). T-MACS and MACS would have allowed 36.3% and 22.5% patients to be immediately discharged respectively. Of patients classified as ‘very low risk’, none had ACS when MACS was used compared to one (0.7%) with T-MACS.

Conclusion

Both MACS and T-MACS effectively ruled out ACS even with a contemporary troponin I assay and could be used to reduce unnecessary hospital admissions.

Le texte complet de cet article est disponible en PDF.

Keywords : Acute coronary syndromes, Clinical decision rules, Cardiac troponin, Sensitivity and specificity


Plan


© 2017  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 36 - N° 4

P. 602-607 - avril 2018 Retour au numéro
Article précédent Article précédent
  • Utility of a Medical Alert Protection System compared to telephone follow-up only for home-alone elderly presenting to the ED — A randomized controlled trial
  • Nicholas Wei Rong Ong, Andrew Fu Wah Ho, Bibhas Chakraborty, Stephanie Fook-Chong, Pasupathi Yogeswary, Sherman Lian, Xiaohui Xin, Juliana Poh, Kelvin Koon Yeow Chiew, Marcus Eng Hock ONG
| Article suivant Article suivant
  • Stair-related injuries treated in United States emergency departments
  • Danielle Herbert Blazewick, Thitphalak Chounthirath, Nichole L. Hodges, Christy L. Collins, Gary A. Smith

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.