S'abonner

Kinect-based real-time audiovisual feedback device improves CPR quality of lower-body-weight rescuers - 19/04/18

Doi : 10.1016/j.ajem.2017.09.022 
Jen-Chun Wang, MD a, Shih-Hung Tsai, MD, PhD a, , Ying-Hsin Chen, MD, PhD a, Yu-Long Chen, MD b, Shi-Jye Chu, MD c, Wen-I Liao, MD a,
a Department of Emergency Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan 
b Department of Emergency Medicine, Buddhist Tzu Chi General Hospital, Taipei Branch, Taipei, Taiwan 
c Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan 

Corresponding authors at: Department of Emergency Medicine, Tri-Service General Hospital, National Defense Medical Center, No. 325, Sec. 2, Cheng-Kung Road, Taipei, Taiwan.Department of Emergency MedicineTri-Service General HospitalNational Defense Medical CenterNo. 325, Sec. 2, Cheng-Kung RoadTaipeiTaiwan

Abstract

Background

Chest compression (CC) quality is associated with rescuer posture and body weight. We designed a Kinect module-based real-time audiovisual feedback (AVF) device to investigate the relationship between rescuer posture, body weight, and CC quality.

Methods

A total of 100 healthcare professionals were enrolled as participants in this randomized trial. A Kinect-based sensor system was used to monitor the depth and rate of CC and provide further real-time feedback. All participants were asked to perform continuous CC on a manikin with and without feedback for 2min individually in either a kneeling or standing position.

Results

A kneeling posture can provide higher rate of CC than a standing posture can (111.4±22.6 per minute vs. 99.1±18.9per minute, p value=0.005). Real-time AVF feedback can provide a better compression depth, rate, and effective compression ratio (6.16±1.88cm vs. 5.54±1.89cm, p value=0.02; 103.2±21.0/min vs. 96.7±25.8/min, p value=0.03; 62.6±28.0% vs. 51.0±33.2%, p value=0.004). Regardless of the effect of real-time feedback, the CC depth correlated to the rescuers' body weight. Rescuers who weighed below 71kg benefited from the Kinect module-based real-time AVF device in terms of improved CC quality.

Conclusion

The Kinect-based AVF device can significantly improve CC quality in manikin training in rescuers with their body weight<71kg.

Le texte complet de cet article est disponible en PDF.

Keywords : Chest compressions, Cardiopulmonary resuscitation, Posture, weight, Kinect, Audiovisual feedback


Plan


 The authors have no potential conflict of interests to disclose.


© 2017  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 36 - N° 4

P. 577-582 - avril 2018 Retour au numéro
Article précédent Article précédent
  • Comparison of IV dexketoprofen trometamol, fentanyl, and paracetamol in the treatment of renal colic in the ED: A randomized controlled trial
  • Behcet Al, Mehmet Mustafa Sunar, Suat Zengin, Mustafa Sabak, Mustafa Bogan, Basri Can, Seval Kul, M. Murat Oktay, Sevki Hakan Eren
| Article suivant Article suivant
  • The potential use of unmanned aircraft systems (drones) in mountain search and rescue operations
  • Yunus Karaca, Mustafa Cicek, Ozgur Tatli, Aynur Sahin, Sinan Pasli, Muhammed Fatih Beser, Suleyman Turedi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.