Permanent pacemaker use among patients with heart failure and preserved ejection fraction: Findings from the Acute Decompensated Heart Failure National Registry (ADHERE) National Registry - 11/04/18

Doi : 10.1016/j.ahj.2017.12.020 
Prateeti Khazanie, MD, MPH a, Anne S. Hellkamp, MS b, Gregg C. Fonarow, MD e, Lesley H. Curtis, PhD b, c, d, Sana M. Al-Khatib, MD, MHS b, d, Adrian F. Hernandez, MD, MHS b, c, d,
a Department of Medicine, University of Colorado Denver, CO 
b Duke Clinical Research Institute, Durham, NC 
c Center for Population Health Sciences, Durham, NC 
d Department of Medicine, Durham, NC 
e Duke University School of Medicine, Durham, North Carolina; and Ahmanson-UCLA Cardiomyopathy Center, University of California, Los Angeles 

Reprint requests: Adrian F. Hernandez, MD, MHS, Duke Clinical Research Institute, PO Box 17969, Durham, NC 27715.Duke Clinical Research InstitutePO Box 17969DurhamNC27715

Abstract

Background

Heart failure with preserved ejection fraction may be associated with chronotropic incompetence, but little is known about the incidence and prevalence of permanent pacemaker use in this population or factors associated with its use.

Methods

We analyzed patients with heart failure with preserved ejection fraction (ie, left ventricular ejection fraction greater than 40%) from the ADHERE registry (2001-2006) linked with Medicare claims. We described the use of both prevalent and incident permanent pacemakers in heart failure with preserved ejection fraction and determined factors associated with pacemaker use with logistic regression models.

Results

Among 13,881 patients with heart failure with preserved ejection fraction, 3136 (22.6%) had a permanent pacemaker, and of these patients, 636 had a permanent pacemaker implanted during hospitalization. Permanent pacemaker use was more common among older patients (81 vs 79 years; P < .001), men (38% vs 34%; P < .001), patients with atrial fibrillation (58% vs 36%; P < .001), and patients with wider QRS duration (140 ms vs 94 ms; P < .001). Rates of digoxin, aldosterone antagonist, and loop diuretic use were slightly higher in patients with a permanent pacemaker compared with patients with no permanent pacemaker. Factors associated with both prevalent and incident pacemaker use included age, fast or slow heart rate, atrial fibrillation, and lower body mass index.

Conclusions

Use of permanent pacemakers is relatively common among patients with heart failure with preserved ejection fraction.

Le texte complet de cet article est disponible en PDF.

Plan


 James B. Young, MD served as guest editor for this article.


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 198

P. 123-128 - avril 2018 Retour au numéro
Article précédent Article précédent
  • Outcomes of hospitalization in adults with Fontan palliation: The Mayo Clinic experience
  • Alexander Egbe, Arooj R. Khan, Mohamad Al-Otaibi, Sameh M. Said, Heidi M. Connolly
| Article suivant Article suivant
  • Efficacy and safety of dabigatran compared with warfarin in patients with atrial fibrillation in relation to renal function over time—A RE-LY trial analysis
  • Ziad Hijazi, Stefan H. Hohnloser, Jonas Oldgren, Ulrika Andersson, Stuart J. Connolly, John W. Eikelboom, Michael D. Ezekowitz, Paul A. Reilly, Salim Yusuf, Lars Wallentin

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.