Variable tibiofemoral articular contact stress in fixed-bearing total knee arthroplasties - 31/03/18

Doi : 10.1016/j.otsr.2017.11.015 
K. Murakami a, S. Hamai a, , T. Moro-oka a, b, K. Okazaki a, H. Higaki c, T. Shimoto d, S. Ikebe c, Y. Nakashima a
a Department of orthopaedic surgery, Graduate school of medical sciences, Kyushu university, 1-3-3, Maidashi, 812-8582 Higashi-ku, Fukuoka, Japan 
b Moro-oka orthopaedic hospital, 101-3, Katawana Nakagawa-machi, 811-1201 Chikushi-gun, Fukuoka, Japan 
c Department of biorobotics, faculty of engineering, Kyushu Sangyo university, 2-3-1, Matsugadai, 813-8583 Higashi-ku, Fukuoka, Japan 
d Department of information and systems engineering, faculty of information engineering, Fukuoka institute of technology, 3-30-1, Wajiro-higashi, 811-0295 Higashi-ku, Fukuoka, Japan 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Rotational allowance at the tibiofemoral joint would be required during deep flexion. However, the amount of flexion and rotation has not been investigated in modern total knee arthroplasty (TKA) designs. The present study aimed to determine the contact stress in five posterior-stabilized fixed-bearing TKA designs.

Hypothesis

We hypothesized that the contact area and stresses at the tibiofemoral articular surfaces vary according to the type of implant design and tested condition.

Materials and methods

The contact area and mean and peak contact stresses at the tibiofemoral articular surfaces were determined when a compressive load of 1200N was applied to a NexGen LPS Flex, Scorpio NRG, Genesis II, PFC Sigma, and Foundation implant. Measurements were performed at 0° and 45° flexion with 0°, 5°, 10°, and 15° rotation, and at 90° and 135° flexion with 0, 5°, 10°, 15°, and 20° rotation.

Results

The LPS Flex showed that the femoral component could not achieve 20° rotation at 135° flexion. The Scorpio NRG showed less than 20MPa of contact stress at all conditions. The Genesis II showed higher contact stress than 20MPa at 135° flexion with 20° rotation. The PFC Sigma showed that the femoral component could not achieve >10° rotation at any flexion angle. The Foundation showed more than 20MPa of contact stress at 90° flexion with 20° rotation and at 135° flexion with 10°, 15°, and 20° rotation.

Discussion

Surgeons should be more aware of the variable contact conditions of the tibiofemoral articular surfaces in individual TKA designs.

Level of evidence

Level IV, basic science study.

Le texte complet de cet article est disponible en PDF.

Keywords : Total knee arthroplasty, Contact stress, Contact area, Axial rotation


Plan


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 104 - N° 2

P. 177-183 - avril 2018 Retour au numéro
Article précédent Article précédent
  • Comparison of mode of failure between primary and revision total knee arthroplasties
  • H. Liang, J.K. Bae, C.H. Park, K.I. Kim, D.K. Bae, S.J. Song
| Article suivant Article suivant
  • Total knee arthroplasty with the Medial-Pivot knee system: Clinical and radiological outcomes at 9.5 years’ mean follow-up
  • M. Dehl, Y. Bulaïd, M. Chelli, R. Belhaouane, A. Gabrion, E. Havet, P. Mertl

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.