S'abonner

Corticocancellous bone graft vs cancellous bone graft for the management of unstable scaphoid nonunion - 23/02/18

Doi : 10.1016/j.otsr.2017.11.011 
J.K. Kim a, , J.O. Yoon a, H. Baek b
a Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea 
b Department of Orthopedic Surgery, Ewha Womans Universtiy Mokdong Hospital, Seoul, South Korea 

Corresponding author. Department of Orthopedic Surgery Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic road 43-gil, Songpa-gu, Seoul 05505, South Korea.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

This study was undertaken to determine whether corticocancellous bone grafting and cancellous bone grafting differ in terms of bone union rate, restoration of scaphoid anatomy, and wrist function when unstable scaphoid nonunions are concomitantly treated by screw fixation.

Materials and methods

This is retrospective cohort study. In Group A (17 patients), unstable scaphoid nonunion was treated with corticocancellous graft harvested from the iliac crest and headless compression screw using volar approach. In Group B (18 patients), unstable scaphoid nonunion was treated with cancellous graft harvested from the distal radius or iliac crest and headless compression screw using volar approach Mean time to union was measured using CT image. Scaphoid deformity was also measured using lateral intrascaphoid angle and height to length ratio using CT images. Wrist functional status was assessed by measuring grip strength, wrist range of motion, and DASH score at 1 year postoperatively.

Results

Mean time to union was significantly greater in Group A (15 weeks vs. 11 weeks). No significant intergroup difference was observed for lateral intrascaphoid angle and height to length ratio after treatment of scaphoid nonunion. No significant intergroup difference was observed for grip strength, wrist range of motion, or DASH scores at 1 year postoperatively.

Conclusions

Cancellous bone grafting was found to lead to earlier bone union than corticocancellous bone grafting and to similar restorations of scaphoid deformity and wrist function when scaphoid nonunion was treated by headless compression screw fixation and bone grafting.

Level of evidence

Prognostic, III.

Le texte complet de cet article est disponible en PDF.

Keywords : Unstable scaphoid nonunion, Cancellous bone graft, Corticocancellous bone graft


Plan


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 104 - N° 1

P. 115-120 - février 2018 Retour au numéro
Article précédent Article précédent
  • Scaphoid screw fixation perpendicular to the fracture plane: Comparing volar and dorsal approaches
  • P.W.L. ten Berg, J.G.G. Dobbe, M.E. Brinkhorst, G. Meermans, S.D. Strackee, F. Verstreken, G.J. Streekstra
| Article suivant Article suivant
  • Results and complications of superficialis-to-profundus tendon transfer in brain-damaged patients, a series of 26 patients
  • E. Peraut, L. Taïeb, C. Jourdan, F. Coroian, I. Laffont, M. Chammas, B. Coulet

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.