Scaphoid screw fixation perpendicular to the fracture plane: Comparing volar and dorsal approaches - 23/02/18

Doi : 10.1016/j.otsr.2017.11.013 
P.W.L. ten Berg a, , J.G.G. Dobbe b, M.E. Brinkhorst c, G. Meermans d, S.D. Strackee a, F. Verstreken e, G.J. Streekstra b, f
a Department of Plastic, Reconstructive, and Hand Surgery, Academic Medical Center, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands 
b Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands 
c Department of Plastic, Reconstructive, and Hand Surgery, Erasmus Medical Center, University Medical Center Rotterdam, 3015 CE Rotterdam, The Netherlands 
d Department of Orthopaedics, Lievensberg Hospital, 4624 VT Bergen Op Zoom, The Netherlands 
e Department of Orthopaedics, Monica Hospital, 2018 Antwerp, Belgium 
f Department of Radiology, Academic Medical Center, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands 

Corresponding author. Department of plastic, reconstructive, and hand surgery, Academic Medical Center, University of Amsterdam, Room G4-226, Meibergdreef 9, 1105AZ Amsterdam, The Netherlands.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

To percutaneously fixate a midwaist scaphoid fracture, both volar and dorsal approaches are considered valid options although they may have different screw insertion angles relative to the scaphoid fracture plane influencing fixation stability. In this virtual simulation study, we investigated the accessibility of placing a screw perpendicularly to the fracture plane in transverse and horizontal oblique scaphoid midwaist fracture models and compared standard volar and dorsal approaches.

Material and methods

Computed tomography scans of 38 healthy wrists were used to obtain virtual 3-dimensional wrist models in flexion and extension. In case the trapezium in volar approach or the distal radius in dorsal approach obstructed the screw axis perpendicular to the fracture plane, an alternative non-obstructed screw axis was chosen as close as possible to the perpendicular axis. The deviation angle between the best possible non-obstructed screw placement and true perpendicular screw placement was quantified.

Results

For transverse fractures, the average deviation angle (±standard deviation) was 8° (±5°) in volar approach, and 0° (±0°) in dorsal approach. For horizontal oblique fractures, these angles were 40° (±6°) and 14° (±8°), respectively.

Discussion

In our simulations, compared to the volar approach, the dorsal approach provided the most precise screw placement perpendicular to the fracture plane, with the largest differences for horizontal oblique fractures. When taken in addition to screw purchase, thread engagement and protrusion risk, information about screw orientation may help surgeons in deciding between percutaneous approaches in scaphoid surgery on which there is currently no consensus.

Level of evidence

N/A.

Le texte complet de cet article est disponible en PDF.

Keywords : Scaphoid fracture, Percutaneous, Screw fixation, Fixation, Dorsal approach, Volar approach


Plan


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 104 - N° 1

P. 109-113 - février 2018 Retour au numéro
Article précédent Article précédent
  • Role for cementoplasty in intra-articular distal radius fractures: Cadaver study and application to arthroscopy
  • V. Fontaine, M. Grunberg, J. Soret, K. El-Youssef, L.-E. Gayet, R. Taberne
| Article suivant Article suivant
  • Corticocancellous bone graft vs cancellous bone graft for the management of unstable scaphoid nonunion
  • J.K. Kim, J.O. Yoon, H. Baek

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.