S'abonner

Virtual Resting Pd/Pa From Coronary Angiography and Blood Flow Modelling: Diagnostic Performance Against Fractional Flow Reserve - 02/02/18

Doi : 10.1016/j.hlc.2017.03.163 
Michail I. Papafaklis, MD, PhD a, , Takashi Muramatsu, MD, PhD b, Yuki Ishibashi, MD b, Christos V. Bourantas, MD, PhD b, Dimitrios I. Fotiadis, PhD c, Emmanouil S. Brilakis, MD, PhD d, Héctor M. Garcia-Garcia, MD, PhD b, Javier Escaned, MD, PhD e, Patrick W. Serruys, MD, PhD b, f, Lampros K. Michalis, MD, MRCP a
a Second Department of Cardiology, Medical School, University of Ioannina, Greece 
b Thoraxcenter, Erasmus Medical Centre, Rotterdam, The Netherlands 
c Department of Materials Science and Engineering, University of Ioannina, Greece 
d Veterans Administration North Texas Healthcare System and University of Texas Southwestern Medical School, Dallas, TX, USA 
e San Carlos University Hospital, Madrid, Spain 
f International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, London, UK 

Corresponding author at: Michailideion Cardiac Center, Medical School, University of Ioannina, Stavrou Niarchou Avenue, 45100 Ioannina, Greece. Tel: +30 6944376572, Fax: +30 2651007865.

Résumé

Background

Fractional flow reserve (FFR) has been established as a useful diagnostic tool. The distal coronary pressure to aortic pressure (Pd/Pa) ratio at rest is a simpler physiologic index but also requires the use of the pressure wire, whereas recently proposed virtual functional indices derived from coronary imaging require complex blood flow modelling and/or are time-consuming. Our aim was to test the diagnostic performance of virtual resting Pd/Pa using routine angiographic images and a simple flow model.

Methods

Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by FFR. The resting Pd/Pa for each lesion was assessed by computational fluid dynamics.

Results

The discriminatory power of virtual resting Pd/Pa against FFR (reference: ≤0.80) was high (area under the receiver operator characteristic curve [AUC]: 90.5% [95% CI: 85.4–95.6%]). Diagnostic accuracy, sensitivity and specificity for the optimal virtual resting Pd/Pa cut-off (≤0.94) were 84.9%, 90.4% and 81.6%, respectively. Virtual resting Pd/Pa demonstrated superior performance (p<0.001) versus 3D-QCA %area stenosis (AUC: 77.5% [95% CI: 69.8–85.3%]). There was a good correlation between virtual resting Pd/Pa and FFR (r=0.69, p<0.001).

Conclusions

Virtual resting Pd/Pa using routine angiographic data and a simple flow model provides fast functional assessment of coronary lesions without requiring the pressure-wire and hyperaemia induction. The high diagnostic performance of virtual resting Pd/Pa for predicting FFR shows promise for using this simple/fast virtual index in clinical practice.

Le texte complet de cet article est disponible en PDF.

Keywords : Coronary stenoses, Fractional flow reserve, Computational flow dynamics, Haemodynamics, Functional assessment


Plan


© 2017  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 27 - N° 3

P. 377-380 - mars 2018 Retour au numéro
Article précédent Article précédent
  • Topical Ice Slush Adversely Affects Sniff Nasal Inspiratory Force After Coronary Bypass Surgery
  • Rakan I. Nazer, Ali M. Albarrati
| Article suivant Article suivant
  • Reproducibility of Cardiac Magnetic Resonance Imaging (CMRI)-Derived Right Ventricular Parameters in Repaired Tetralogy of Fallot (ToF)
  • Ganesh Kumar Gnanappa, Imran Rashid, David Celermajer, Julian Ayer, Rajesh Puranik

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.