S'abonner

Traitement de l’incontinence urinaire masculine neurologique par le sphincter urinaire artificiel AMS 800™ (Boston Scientific, Boston, États-Unis) : résultats à très long terme (> 25 ans) - 10/01/18

Male neurogenic stress urinary incontinence treated by artificial urinary sphincter AMS 800™ (Boston Scientific, Boston, USA): Very long-term results (> 25 years)

Doi : 10.1016/j.purol.2017.09.012 
C. Guillot-Tantay a, , E. Chartier-Kastler a, P. Mozer a, M.-O. Bitker a, F. Richard a, V. Ambrogi a, P. Denys b, P. Léon a, V. Phé a
a Service d’urologie et de transplantation rénale, hôpital universitaire La Pitié Salpêtrière, Assistance publique–Hôpitaux de Paris, faculté de médecine Pierre et Marie Curie, Sorbonne universités, université Paris 6, 47-83, boulevard de L’hôpital, 75013 Paris, France 
b Service de médecine physique et réadaptation, hôpital Raymond-Poincaré, Assistance publique–Hôpitaux de Paris, UFR des sciences de la santé Simone Veil, université Versailles-Saint-Quentin-en-Yvelines, 104, boulevard Raymond-Poincaré, 92380 Garches, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 3
Vidéos 0
Autres 0

Résumé

Objectif

Le but de cette étude était d’évaluer les résultats fonctionnels à très long terme du sphincter urinaire artificiel (SUA) implanté chez les hommes neurologiques.

Matériels et méthodes

Tous les hommes neurologiques implantés avec un SUA (AMS 800®) dans notre institution entre 1985 et 1992 ont été inclus. La continence, définie par l’absence de port de protections, les taux d’explantation et de révision ont été évalués.

Résultats

Au total, quatorze patients d’âge médian 27,3 ans (IQ : 27,3,5–40,8) ont été inclus : quatre étaient des blessés médullaires et dix avaient un spina bifida. Un antécédent de chirurgie de la continence était rapporté chez six patients (42,9 %). Le SUA a été implanté en position péribulbaire (n=4) ou périprostatique (n=10). La durée médiane de suivi était de 18,3 ans (IQR : 10,1–20,3). Tous les patients étaient vivants au terme du suivi. Trois SUA étaient natifs, huit furent révisés (dont quatre furent explantés dans un second temps) et trois explantés pour infection ou érosion. Le taux de survie sans explantation à 5, 10, 15 et 20 ans était de 85,7 %, 62,3 %, 52,0 % et 39,0 % respectivement. Le taux de survie sans révision à 5, 10, 15 et 20 ans était de 78,6, 42,9, 28,6 et 7,1 %, respectivement. Au terme du suivi, 50 % des patients étaient continents.

Conclusion

À très long terme, le SUA a permis d’obtenir un taux de continence de 50 % chez les hommes neurologiques au prix d’un taux de révision important.

Niveau de preuve

4.

Le texte complet de cet article est disponible en PDF.

Summary

Objective

The aim of the study was to report the very long-term functional outcomes of artificial urinary sphincter (AUS) in male neurological patients.

Material and methods

Male neurological patients diagnosed with stress urinary incontinence due to sphincter deficiency and undergoing AUS (AMS 800®) implantation between 1985 and 1992 were enrolled. Continence, defined by no pad/condom usage, explantation and revision rates were reported.

Results

Fourteen patients with a median age of 27.3 years (IQR: 27.3–40.8) were included: four had a spinal cord injury and ten a spina bifida. Prior continence surgery was reported by 6 patients (42.9 %). Artificial urinary sphincter was implanted in a peribulbar (n=4) or periprostatic position (n=10). Median follow-up was 18.3 years (IQR: 10.1–20.3). At last follow-up, all patients were alive. Three native devices were still in place, eight were revised (four of them were secondarily explanted) and three were explanted due to erosion or infection. The 5-, 10-, 15-, 20-year explantation-free survival rates were respectively 85.7, 62.3, 52.0, 39.0 %. The 5-, 10-, 15-, 20-year revision-free survival rates were respectively 78.6, 42.9, 28.6, 7.1 %. At last follow-up, 50 % patients were continent.

Conclusion

In the very long run, AUS provided a 50 % continence rate in male neurological patients but the revision rates were important.

Level of evidence

4.

Le texte complet de cet article est disponible en PDF.

Mots clés : Sphincter urinaire artificiel, Neuro-urologie, Insuffisance sphinctérienne, Incontinence urinaire, Autosondage

Keywords : Artificial urinary sphincter, Neuro-urology, Intrinsic sphincter deficiency, Urinary incontinence, Self-catheterisation


Plan


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 28 - N° 1

P. 39-47 - janvier 2018 Retour au numéro
Article précédent Article précédent
  • Conséquences psychologiques du cancer de prostate chez les patients traités par une forme semestrielle d’hormonothérapie
  • A. de la Taille, S. Mardoyan, A. Lafaye
| Article suivant Article suivant
  • Robot-assisted renal transplantation using the retroperitoneal approach (RART) with more than one year follow up: Description of the technique and results
  • F. Bruyère, B. Pradère, B. Faivre d’Arcier, J.-M. Boutin, M. Buchler, N. Brichart

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.