A novel flexible drill device enabling arthroscopic transosseous repair of Bankart lesions - 29/11/17
Abstract |
We have developed a flexible drill device that makes arthroscopic transosseous repair possible, and report preliminary results. Twelve patients with post-traumatic anterior inferior glenohumeral instability were selected. Surgical technique: the flexible drill device is inserted into the shoulder joint through the posterior portal and the guide pipe unit is placed 5mm posterior to the margin of the anterior glenoid rim. The flexible drill is driven through the glenoid with the power drill, creating a hole in the glenoid. A non-absorbable suture is passed through the hole and a sliding knot tying is performed over the capsule and labrum after completing stitches with the suture hook loaded. The same procedures are repeated in the 2, 3 and 4 o’clock positions of the glenoid. There was no recurrence of dislocation at the mean follow-up period of 52.3 months. The mean Rowe score was 89.5.
Le texte complet de cet article est disponible en PDF.Keywords : Bankart lesion, Transosseous repair, Flexible drill
Plan
Vol 103 - N° 4
P. 499-504 - juin 2017 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.