S'abonner

Differentiation between idiopathic granulomatous mastitis and malignant breast lesions using strain ratio on ultrasonic elastography - 15/11/17

Doi : 10.1016/j.diii.2017.06.009 
B. Yağcı a, I. Erdem Toslak a, b, , B. Çekiç a, M. Öz a, B.R. Karakaş c, M. Akdemir d, S. Yıldız a, D. Süren e, D. Bova b
a Department of Radiology, Antalya Training and Research Hospital, Health Sciences University, Antalya, Turkey 
b Department of Radiology, Loyola University Medical Center, Maywood, Illinois, USA 
c Department of General Surgery, Antalya Training and Research Hospital, Health Sciences University, Antalya, Turkey 
d Department of Public Health, Akdeniz University Medical School,Antalya, Turkey 
e Department of Pathology, Antalya Training and Research Hospital, Health Sciences University, Antalya, Turkey 

Corresponding author at: Department of Radiology, Antalya Training and Research Hospital, Health Sciences University, Antalya, Turkey.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

The goal of this study was to investigate the strain elastography imaging characteristics of idiopathic granulomatous mastitis (IGM) and compare strain ratio values of IGM with those of breast cancer.

Material and methods

Twenty-three consecutive women with IGM (mean age, 37.9±6.6 [SD] years; range: 26–52 years) and 45 women with malignant breast tumor (mean age, 52.8±12.0 [SD], range, 32–77 years) who had been scheduled for ultrasound-guided core biopsy were recruited to the study. All had ultrasonography with elastography before biopsy. The strain ratios of lesions were calculated using surrounding normal breast tissue as the reference in both groups and compared between the two groups. Receiver-operating-characteristics (ROC) curves were formed. Sensitivity, specificity, cut-off, and area under curve (AUC) values were calculated.

Results

The mean strain ratio on sonoelastography was 1.5±0.8 (SD) (range: 0.2–4.0) for IGM and 5.3±5.2 (SD) (range: 1.4–33) for malignant lesions. Strain ratio values in IGM lesions were significantly lower than in malignant lesions (P˂0.05). ROC test yielded an AUC value of 0.939 (95% confidence interval, 0.882–0.995; P<0.0001). Optimal cut-off value for strain ratio value was 2.5 yielding 87% sensitivity and 96% specificity for the diagnosis of IGM.

Conclusion

Sonoelastographic strain ratio contributes to differentiate IGM from malignant breast lesions, thus has potential to influence clinical decision making for further biopsies.

Le texte complet de cet article est disponible en PDF.

Keywords : Ultrasonography, Elastography, Strain ratio, Granulomatous mastitis, Breast cancer

Abbreviations : UE, IGM, SR


Plan


© 2017  Editions françaises de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 10

P. 685-691 - octobre 2017 Retour au numéro
Article précédent Article précédent
  • Evaluation of MR imaging-targeted biopsies of the prostate in biopsy-naïve patients. A single centre study
  • J. Garcia Bennett, J.C. Vilanova, J. Gumà Padró, D. Parada, A. Conejero
| Article suivant Article suivant
  • Diagnostic value of 18F-FDG-PET/CT for the follow-up and restaging of soft tissue sarcomas in adults
  • T.W. Kassem, O. Abdelaziz, S. Emad-Eldin

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.