Abstract

Introduction

Short hip stems, intended to conserve bone stock and ensure a more physiological distribution of stress in the femur under loading, are meeting with renewed interest. Radiologic semiology is not known exactly, particularly in relation to conventional implants; we therefore conducted a case-control study of 3 types of implant differing only in stem length: short, shortened or long. The aim was: (1) to compare radiographic aspects, (2) to attempt to systematize medium-term radiologic status for the 3 types, and (3) to assess the impact of radiographic aspect on loosening and revision rates.

Hypothesis

The short Metha stem is better adapted to the recipient bone than longer stems, without sacrificing stability.

Material and methods

A prospective series comprising the first 100 selected cases of hip replacement using the short Metha stem was compared to two other series of 100 “long” (Omnifit HA) and 100 “shortened” (ABG II) stems at comparable follow-up: 4.05±1.44years (range: 2–8years) for Metha, 4.48±0.97years (range: 2–8years) for Omnifit, and 4.75±2.07years (range: 2–8years) for ABG II. Selection criteria in this initial phase were very strict: young age and/or high activity level, with good bone stock and femoral morphology suited to fitting a Metha stem (no “stovepipe” or “champagne-flute” femurs), for which 12.8% of primary hip replacements were selected. Matching was performed by sampling on criteria of age, gender, body-mass index and etiology. Radiographic parameters were compared between the short stem group and the two control groups and classified according to Engh-Massin score (10 points for fixation and 17 for stability).

Results

The short Metha stem provided excellent fixation scores: 7.65/10, versus 7.16 (P=0.003) and 5.92 (P=0.0001) for ABG II and Omnifit, respectively. Likewise, stability was scored 14.23/17 for Metha, vs. 14.51 (NS) and 11.83 (P=0.0001) respectively, and the total score was higher for Metha (21.88/27) than ABG II (21.67; P=0.03) or, more particularly, Omnifit (17.83; P=0.0001). The Metha stem was never associated with thigh pain or periprosthetic fracture. 8-year survival was 100%, without significant difference with respect to ABG II (100%; NS) or Omnifit (98.8%; 95% CI: 0.964-1; NS).

Discussion

The apparent radiologic superiority of the short Metha stem requires long-term confirmation in non-selected series. Meanwhile, Metha can be asserted to have demonstrated optimal compromise between lasting bone anchorage and respect of bone physiology under loading at medium term.

Level of evidence

III, case-control study.

Le texte complet de cet article est disponible en PDF.

Keywords : Hip replacement, Short stem, Radiological analysis, Metha, Hip stem length, Comparative predictive study


Plan


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 7

P. 981-986 - novembre 2017 Retour au numéro
Article précédent Article précédent
  • Redefining knee replacement
  • P.-A. Vendittoli, W. Blakeney
| Article suivant Article suivant
  • Long-term survivorship of the Corail™ standard stem
  • L. Louboutin, A. Viste, R. Desmarchelier, M.-H. Fessy

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.