S'abonner

Reconstruction of large diaphyseal bone defect by simplified bone transport over nail technique: A 7-case series - 07/11/17

Doi : 10.1016/j.otsr.2017.05.016 
F. Ferchaud , L. Rony , F. Ducellier , P. Cronier , V. Steiger , L. Hubert

the Orthopedics and Traumatology Society of Western France (SOO)

 Service de chirurgie orthopédique, CHU Angers, 4, rue Larrey, 49100 Angers, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Reconstruction of large diaphyseal bone defect is complex and the complications rate is high. This study aimed to assess a simplified technique of segmental bone transport by monorail external fixator over an intramedullary nail.A prospective study included 7 patients: 2 femoral and 5 tibial defects. Mean age was 31years (range: 16–61years). Mean follow-up was 62 months (range: 46–84months). Defects were post-traumatic, with a mean length of 7.2cm (range: 4 to 9.5cm). For 3 patients, reconstruction followed primary failure. In 4 cases, a covering flap was necessary. Transport used an external fixator guided by an intramedullary nail, at a rate of 1mm per day. One pin was implanted on either side of the distraction zone. The external fixator was removed 1 month after bone contact at the docking site. Mean bone transport time was 11 weeks (range: 7–15 weeks). Mean external fixation time was 5.1months (range: 3.5 to 8months). Full weight-bearing was allowed 5.7months (range: 3.5–13months) after initiation of transport. In one patient, a pin had to be repositioned. In 3 patients, the transported segment re-ascended after external fixatorablation, requiring repeat external fixation and resumption of transport. There was just 1 case of superficial pin infection. Reconstruction quality was considered “excellent” on the Paley-Marr criteria in 6 cases. The present technique provided excellent reconstruction quality in 6 of the 7 cases. External fixation time was shorter and resumption of weight-bearing earlier than with other reconstruction techniques, notably including bone autograft, vascularized bone graft or the induced membrane technique. Nailing facilitated control of limb axis and length. The complications rate was 50%, comparable to other techniques. This study raises the question of systematic internal fixation of the docking site, to avoid any mobilization of the transported segment. The bone quality, axial control and rapidity shown by the present technique make it well-adapted to reconstruction of diaphyseal bone defect.

Level of evidence

Four-case series.

Le texte complet de cet article est disponible en PDF.

Keywords : Diaphyseal bone defect, Bone transport over a nail, Monorail external fixator


Plan


 Article issued from the SOO (the Orthopedics and Traumatology Society of Western France).


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 7

P. 1131-1136 - novembre 2017 Retour au numéro
Article précédent Article précédent
  • Reverse shoulder arthroplasty in young patient with achondroplasia – Ten year follow up: Case report
  • M. van den Broek, O. Verborgt, G. Declercq
| Article suivant Article suivant
  • Erratum to “What are the risk factors for dislocation in primary total hip arthroplasty? A multicenter case-control study of 128 unstable and 438 stable hips” [Orthop. Traumatol. Surg. Res. 103 (2017) 663–8]
  • M.H. Fessy, S. Putman, A. Viste, R. Isida, N. Ramdane, A. Ferreira, A. Leglise, B. Rubens-Duval, N. Bonin, F. Bonnomet, A. Combes, S. Boisgard, D. Mainard, S. Leclercq, H. Migaud, Société Française de chirurgie de la Hanche et du Genou (SFHG) n

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.