Comparison of the McGrath® MAC video laryngoscope with direct Macintosh laryngoscopy for novice laryngoscopists in children without difficult intubation: A randomised controlled trial - 07/11/17
pages | 5 |
Iconographies | 0 |
Vidéos | 0 |
Autres | 0 |
Highlights |
• | There is still a debate regarding intubation time with video laryngoscopes and few paediatric studies focus on the McGrath® MAC video laryngoscope. |
• | The use of the McGrath® MAC video laryngoscope is associated with a longer time to intubation by novice laryngoscopists when compared with direct laryngoscopy on easy-to-intubate children. |
Abstract |
Introduction |
Airway management and tracheal intubation are routinely performed in paediatric anaesthesia and yet are associated with preventable adverse events. The McGrath® MAC is a video laryngoscope with a curved blade similar to the Macintosh blade, which has not been previously described in first intention paediatric tracheal intubation. We aimed to compare direct laryngoscopy to the McGrath® MAC video laryngoscope among novice laryngoscopists.
Methods |
Six paediatric anaesthesia residents with novice skills in paediatric laryngoscopy were randomly assigned to perform tracheal intubation using either direct Macintosh laryngoscopy (DL) or the McGrath® MAC video laryngoscope (MM) as the first attempted device in children weighing between 10 and 20kg without difficult intubation.
Results |
Our study enrolled 132 children between August 2013 and April 2015. The time to intubation was shorter in the DL group (n=67) compared to the MM group (n=65) with 42s (35–50) versus 48s (43–58) P=0.002. The time to best view was similar between the two groups (10s [7–16] versus 10s [8–15]; P=0.50). The tube passage time was shorter with DL (29s [25–35] versus 35s [30–45]; P=0.0002) and either Cormak & Lehane grade or Percentage Of Glottis Opening (POGO) scores were similar between groups. Minor reversible respiratory adverse events were similar between groups: 12 in the DL group (17.9%) versus 12 in the MM group (18.5%).
Discussion |
McGrath® MAC video laryngoscopy, when performed by a novice laryngoscopist on easy-to-intubate children, is associated with longer intubation times.
Le texte complet de cet article est disponible en PDF.Keywords : Tracheal intubation, Laryngoscopes, Video laryngoscopes, Paediatric, Curved blades, Internship and residency
Plan
Vol 36 - N° 5
P. 261-265 - octobre 2017 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.
Déjà abonné à cette revue ?