S'abonner

A novel anterior approach for the fixation of ulnar coronoid process fractures - 16/09/17

Doi : 10.1016/j.otsr.2017.05.020 
X. Yang a, 1, W. Chang b, 1, W. Chen b, S. Liu b, Y. Zhu b, Y. Zhang b,
a Second division of department of orthopedic surgery, affiliated hospital of Chengde medical college, 067000 Chengde, P.R. China 
b Department of orthopedic surgery, the third hospital of hebei medical university, NO.139 Ziqiang road, 050051 Shijiazhuang, P.R. China 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

There is no universally accepted approach to the elbow for the fixation of coronoid process fractures. This study aims to introduce a novel anterior surgical approach for the fixation of the ulnar coronoid fracture, with minimal surgical dissection damage and excellent visualization for reduction and internal fixation.

Hypothesis

The anterior approach can facilitate satisfactory outcomes for coronoid process fractures.

Material and methods

From February 2010 to July 2014, 12 patients (8 males and 4 females; range 14–62years; mean age 31years) with a closed fracture of the coronoid process of the ulna were included in this study. According to Adams classification, we included 5 type II, 3 type III, 3 type IV AM, and 1 type IV AL. The fractures were treated operatively via an anterior approach between nerves and blood vessels. The anatomical reduction and fixation with cannulated screws or a mini plate was easily performed. One elbow showed significant joint instability, necessitating, another incision to repair the lateral collateral ligament, and a subsequent operation with a hinged external fixator was required. The remaining patients received a splint for 2 weeks followed by functional exercises.

Results

Mean follow-up was 21 months (13–36). Fracture union was achieved in each patient. The arc of elbow flexion and extension were (135±15)°, and forearm pronation/supination were restored to (165±15)°. When compared with the normal side, there was no significant difference in the functional outcome (P>0.05). According to Morrey’ scale, the functional recovery of the injured arms was assessed as excellent in eleven patients and good in one. Mild heterotopic ossification was found in one case, which had not impaired the elbow function. No other complications were noted.

Conclusions

The anterior approach has the benefits of simplicity, safety, minimal invasion, excellent exposure, and satisfactory prognosis for coronoid process fractures.

Level of evidence

Prospective study, Level IV.

Le texte complet de cet article est disponible en PDF.

Keywords : Elbow, Coronoid process, Fracture, Anterior approach, Space between nerves and blood vessels, Internal fixation


Plan


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 6

P. 899-904 - octobre 2017 Retour au numéro
Article précédent Article précédent
  • First-line management of distal humerus fracture by total elbow arthroplasty in geriatric traumatology: Results in a 21-patient series at a minimum 2 years’ follow-up
  • D. Lami, M. Chivot, A. Caubere, A. Galland, J.N. Argenson
| Article suivant Article suivant
  • Non-operative treatment of displaced distal radius fractures leads to acceptable functional outcomes, however at the expense of 40% subsequent surgeries
  • M.A.M. Mulders, P.V. van Eerten, J.C. Goslings, N.W.L. Schep

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.