S'abonner

Lung ultrasonography to diagnose pneumothorax of the newborn - 21/08/17

Doi : 10.1016/j.ajem.2017.04.001 
Jing Liu, MD, PhD a, c, , Jing-Han Chi, MD b, c, Xiao-Ling Ren, MD a, c, Jie Li, MD a, Ya-Juan Chen, MD a, c, Zu-Lin Lu, MD a, Ying Liu, MD a, Wei Fu, MD a, c, Rong-Ming Xia, MD a
a Department of Neonatology and NICU, Beijing Chaoyang District Maternal and Child Health Care Hospital, Beijing 100101, China 
b Graduate School of Southern Medical University, Guangzhou City 510515, China 
c Department of Neonatology and NICU of Bayi Children's Hospital, The Army General Hospital of the Chinese PLA, Beijing 100700, China 

Corresponding author at: Department of Neonatology and NICU, Beijing Chaoyang District Maternal and Child Health Care Hospital, No. 25 Huaweili, Chaoyang District, Beijing 100101, China.Department of Neonatology and NICUBeijing Chaoyang District Maternal and Child Health Care HospitalNo. 25 Huaweili, Chaoyang DistrictBeijing100101China

Abstract

Objective

To explore the reliability and accuracy of lung ultrasound for diagnosing neonatal pneumothorax.

Methods

This study was divided into two phases. (1) In the first phase, from January 2013 to June 2015, 40 patients with confirmed pneumothorax had lung ultrasound examinations performed to identify the sonographic characteristics of neonatal pneumothorax. (2) In the second phase, from July 2015 to August 2016, lung ultrasound was undertaken on 50 newborn infants with severe lung disease who were suspected of having pneumothorax, to evaluate the sonographic accuracy and reliability to diagnose pneumothorax.

Results

(1) The main ultrasonic manifestations of pneumothorax are as follows: ① lung sliding disappearance, which was observed in all patients (100%); ② the existence of the pleural line and the A-line, which was also observed in all patients (100%); ③ the lung point, which was found in 75% of the infants with mild-moderate pneumothorax but not found to exist in 25% of the severe pneumothorax patients; ④ the absence of B-lines in the area of the pneumothorax (100% of the pneumothorax patients); and ⑤ no lung consolidation existed in the area of the pneumothorax (100% of the pneumothorax patients). (2) The accuracy and reliability of the lung sonographic signs of lung sliding disappearance as well as the existence of the pleural line and the A-line in diagnosing pneumothorax were as follows: 100% sensitivity, 100% specificity, 100% positive predictive value, and 100% negative predictive value. When the lung point exists, the diagnosis is mild-moderate pneumothorax, whereas if no lung point exists, the diagnosis is severe pneumothorax.

Conclusion

Lung ultrasound is accurate and reliable in diagnosing and ruling out neonatal pneumothorax and, in our study, was found to be as accurate as chest X-ray.

Le texte complet de cet article est disponible en PDF.

Keywords : Lung ultrasound, Pneumothorax, Lung sliding, Pleural line, A-line, Newborn infants


Plan


 Every author contributed equally to this work.


© 2017  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 35 - N° 9

P. 1298-1302 - septembre 2017 Retour au numéro
Article précédent Article précédent
  • The relative contribution of provider and ED-level factors to variation among the top 15 reasons for ED admission
  • Imad Khojah, Suhui Li, Qian Luo, Griffin Davis, Jessica E. Galarraga, Michael Granovsky, Ori Litvak, Samuel Davis, Robert Shesser, Jesse M. Pines
| Article suivant Article suivant
  • Effectiveness of finger-marker for maintaining the correct compression point during paediatric resuscitation: A simulation study
  • Jae Yun Jung, Young Ho Kwak, Hyuksool Kwon, Yoo Jin Choi, Do Kyun Kim, Hee Chan Kim, Jung Chan Lee, Ji Heum Park, Hyungsoo Lim

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.