S'abonner

Can a target zone safer than Lewinnek's safe zone be defined to prevent instability of total hip arthroplasties? Case-control study of 56 dislocated THA and 93 matched controls - 18/08/17

Doi : 10.1016/j.otsr.2017.05.015 
N. Reina a, , S. Putman b, R. Desmarchelier c, E. Sari Ali d, P. Chiron a, M. Ollivier e, J.Y. Jenny f, D. Waast g, C. Mabit h, E. de Thomasson i, C. Schwartz j, P. Oger k, L.E. Gayet l, H. Migaud b, N. Ramdane m, M.H. Fessy c

SFHG1

  Société française de chirurgie de la hanche et du genou, 52, rue Boissonade, Paris, France.

a Institut locomoteur (ILM), hôpital Pierre-Paul-Riquet, CHU de Toulouse, 31059 Toulouse, France 
b Hôpital Salengro, CHU de Lille, place de Verdun, 59000 Lille, France 
c Service de chirurgie orthopédique et traumatologique, hospices civils de Lyon, centre hospitalier Lyon-Sud, université de Lyon, 69002 Pierre-Bénite, France 
d Service de chirurgie orthopédique et traumatologique, hôpital la Pitié-Salpétrière, 47-83, boulevard de l’Hôpital, 75013 Paris, France 
e Service de chirurgie orthopédique et traumatologique, hôpital St. Marguerite, 13009 Marseille, France 
f Service de chirurgie orthopédique et traumatologique, hôpital de Hautepierre, CHU de Strasbourg, 67091 Strasbourg, France 
g Service de chirurgie orthopédique et traumatologique, Hôtel-Dieu, 1, place Alexis-Ricordeau, 44093 Nantes, France 
h Service de chirurgie orthopédique et traumatologique, CHU Dupuytren, avenue M.-Luther-King, CHU de Limoges, 87000 Limoges, France 
i Institut mutualiste Montsouris, 42, boulevard Jourdan, 75014 Paris, France 
j Centre d’orthopédie clinique des 3-frontières, 68300 Saint-Louis, France 
k Hopital A.-Mignot, 177, route De-Versailles, 78150 Le Chesnay, France 
l Service de chirurgie orthopédique et traumatologique, CHU de Poitiers, 86021 Poitiers, France 
m Unité de biostatistique, pôle de santé publique, CHRU de Lille, 59000 Lille, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Various factors contribute to instability of total hip arthroplasty (THA), with implant orientation being a major contributor. We performed a case-control study with computed tomography (CT) data to determine whether: 1) orientation contributes to THA instability and 2) a safer target zone for stability than Lewinnek's classic safe zone can be defined.

Material and methods

We included prospectively 363 cases of THA dislocation that occurred during the calendar 2013 year in 24 participating hospitals. Of the 128 dislocations that occurred in patients who underwent THA at these centers, 56 (24 anterior, 32 posterior) had CT scans, thus were included in the analysis. The control group was matched 4:1 based on implant type, year of implantation, age, sex, bearing types and THA indication. Of the 428 matched control THA cases, 93 had CT scans. In all, the CT scans from 149 cases (56 unstable, 93 stable) were analyzed to determine the acetabular cup's inclination and anteversion, and the femoral stem's anteversion.

Results

In the unstable THA group, cup inclination was 46.9°±7.4°, cup anteversion was 20.4°±10.8° and stem anteversion was 14.2°±9.9°. In the stable THA group, cup inclination was 44.9°±5.3° (P=0.057), cup anteversion was 22.1°±5.1° (P=0.009) and stem anteversion was 13.4°±4.4° (P=0.362). The optimal total anteversion (cup+stem) of 40–60° was achieved in 16.5% of unstable THA cases and 13.9% of stable THA cases, thus this parameter does not predict stability (odds ratio [OR] of 0.40, P=0.144). The cup was positioned in Lewinnek's safe zone in 44.6% of patients in the unstable group and 68.2% of those in the stable group (OR 3.74, P=0.003). A target zone defined as 40–50° inclination and 15–30° anteversion was better able to distinguish between unstable cases (23.2%) and stable cases (71.6%) resulting in an OR of 13.91 (P<0.001).

Discussion

Implant positioning was the only risk factor for instability found in this study. Moreover, our findings reinforce the theory put forward by other authors that Lewinnek's safe zone is not specific enough to differentiate between stable and unstable THA implantations. The target zone for acetabular cups proposed here (40–50° inclination and 15°–30° anteversion) is related to a lower risk of instability. This orientation can be used as a guide, but must be combined with other technical elements to optimize stability. By balancing stability and biomechanics, the 40–50° inclination and 15°–30° anteversion target zone redefines the optimal positioning window.

Level of evidence

III case-control study.

Le texte complet de cet article est disponible en PDF.

Keywords : THA, Dislocation, Safe zone, Approach


Plan


 Work of the French Hip & Knee Society (SFHG).


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 5

P. 657-661 - septembre 2017 Retour au numéro
Article précédent Article précédent
  • Hip-spine syndrome: A cadaveric analysis between osteoarthritis of the lumbar spine and hip joints
  • D.S. Weinberg, J.J. Gebhart, R.W. Liu
| Article suivant Article suivant
  • What are the risk factors for dislocation in primary total hip arthroplasty? A multicenter case-control study of 128 unstable and 438 stable hips
  • M.H. Fessy, S. Putman, A. Viste, R. Isida, N. Ramdane, A. Ferreira, A. Leglise, B. Rubens-Duval, N. Bonin, F. Bonnomet, A. Combes, S. Boisgard, D. Mainard, S. Leclercq, H. Migaud, SFHG 1

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.