High-sensitivity C-reactive protein is an independent marker of abnormal coronary vasoreactivity in patients with non-obstructive coronary artery disease - 01/08/17
Abstract |
Background |
Coronary endothelial dysfunction (CED) is an early stage of atherosclerosis and is associated with adverse cardiovascular events. Inflammation may play a role in the development of endothelial dysfunction. To date no study has evaluated the relationship between C-reactive protein and CED. We aimed to determine if C-reactive protein is associated with CED.
Methods |
In 1016 patients (mean age 50.7±12.3 years, 34% male) presenting to the catheterization laboratory with chest pain and non-obstructive coronary artery disease, coronary vasoreactivity was assessed by measuring the percent change in coronary blood flow (%ΔCBF) and coronary artery diameter (%ΔCAD) in response to intracoronary acetylcholine. Plasma high sensitivity C-reactive protein (hs-CRP) was measured and patients were divided into 2 groups: hs-CRP≤3.0 mg/L (low-intermediate cardiovascular risk n=169) and 3 mg/L<hs-CRP≤10 mg/L (high cardiovascular risk n=847).
Results |
Patients with a high risk hs-CRP had a significantly lower %ΔCBF and %ΔCAD in response to acetylcholine vs low risk hs-CRP (43.8±6.1 vs 65.8±4.5, P=.004 and −17.2±1.5 vs −13.1±0.8, P=.02 respectively). Low risk hs-CRP was associated with significantly higher %ΔCBF and %ΔCAD vs high risk hs-CRP (27.1±11.0, P=.01 and 4.5±1.9, P=.02 respectively). CED was associated with significantly higher hs-CRP levels and high risk hs-CRP was independently associated with abnormal coronary vasoreactivity, OR 1.82 (95% CI 1.25–2.69).
Conclusions |
Hs-CRP is independently associated with and a strong predictor of abnormal coronary vasoreactivity in patients with non-obstructive coronary artery disease.
Le texte complet de cet article est disponible en PDF.Abbreviations : BMI, CAD, CBF, CFR, HDL, Hs-CRP, LDL, MI, %ΔCAD Ach, %ΔCBF Ach
Plan
All authors contributed significantly to this manuscript and have read and approved of the final version. |
|
Conflicts of Interest and Relevant Relationships with Industry: Dr. Amir Lerman is a member of the advisory board of Itamar Medical, a company that produces EndoPAT, a device for noninvasive endothelial function detection. This device was not used in this study. Dr. Lilach O. Lerman is his spouse. |
Vol 190
P. 1-11 - août 2017 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?