Abstract

Purpose

The goal of this study was to assess the distal dispersion, the adhesion strength to catheter, the vascular toxicity and the ability in excluding embolized vessels using Purefill® (α-hexil-cyanoacrylate) as embolic material, which is a new high purity cyanoacrylate and compare these results with those obtained with N-butyl-2-cyanoacrylate (Histoacryl®) and a mixture of N-butyl-2-cyanoacrylate and methacryloxysulfolane.

Material and methods

In six pigs, the right rete mirabile (RM) and right renal arteries were embolized with α-hexil-cyanoacrylate, and the left rete mirabile and left renal artery were embolized with N-butyl-2-cyanoacrylate and N-butyl-2-cyanoacrylate+Methacryloxysulfolane for comparison. One minute after glue injection through the microcatheter, displacements of the kidney and the pharyngeal artery were measured on angiographic images, before exercising any traction and during catheter pulling, when the forces were maximal. Displacement was measured in terms of distance (mm) with respect to renal pedicles and in terms of angle (°) with respect to the rete. After acute embolization (4 pigs) or three-month follow-up (2 pigs), the kidneys and the RM were removed and further analysed using computed tomography and histopathological examination.

Results

Similar short and long-term embolic efficacies were observed with the three glues. The mean displacement distances of renal pedicles were 2.6mm for α-hexil-cyanoacrylate, 22.6mm for N-butyl-2-cyanoacrylate and 19.8mm for N-butyl-2-cyanoacrylate+Methacryloxysulfolane (P=0.021). The mean angles of displacement of the ascending pharyngeal arteries were for 12.2° for α-hexil-cyanoacrylate, 23.5° for N-butyl-2-cyanoacrylate and 30° for N-butyl-2-cyanoacrylate+Methacryloxysulfolane (P=0.070). Histopathologically, findings were similar for the three glues, immediately and 90 days after embolization.

Conclusion

α-hexil-cyanoacrylate has occlusive efficacy in the short and long term similar to those of N-butyl-2-cyanoacrylate and N-butyl-2-cyanoacrylate+Methacryloxysulfolane. In addition, histopathological changes are similar with the three glues immediately or 90 days after embolization. Conversely, α-hexil-cyanoacrylate results in a reduced angle and distance of displacement compared to the other two glues, assumably reflecting a limited adhesive strength.

Le texte complet de cet article est disponible en PDF.

Keywords : Interventional radiology, Arterial embolization, Cyanoacrylate, Embolic material, Purefill


Plan


© 2016  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 97 - N° 11

P. 1109-1116 - novembre 2016 Retour au numéro
Article précédent Article précédent
  • Short- and long-term evolution of the endoluminal diameter of underdilated stents in transjugular intrahepatic portosystemic shunt
  • S. Borghol, J.M. Perarnau, J. Pucheux, L. D’Alteroche, J. Ayoub, H. Trillaud
| Article suivant Article suivant
  • Percutaneous treatment of extrahepatic recurrence of hepatocellular carcinoma
  • A. Doreille, G. N’Kontchou, A. Halimi, F. Bouhafs, E. Coderc, N. Sellier, O. Seror

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.