S'abonner

Preoperative planning for accurate glenoid component positioning in reverse shoulder arthroplasty - 21/04/17

Doi : 10.1016/j.otsr.2016.12.019 
J. Berhouet a, b, , L.V. Gulotta a, b, D.M. Dines a, E. Craig a, R.F. Warren a, D. Choi c, X. Chen c, A. Kontaxis b
a Hospital for Special Surgery, Department of Sports Medicine and Shoulder, 535 E 70th St., New York, NY 10021, USA 
b Hospital for Special Surgery, The Leon Root, Motion Analysis Laboratory, 510 E 73rd St., New York, NY 10021, USA 
c Hospital for Special Surgery, Biomechanical Laboratory, 510 E 73rd St., New York, NY 10021, USA 

Corresponding author at: Hospital For Special Surgery, Department of Sports Medicine and Shoulder, 535 E 70th St., New York, NY 10021, USA.Hospital For Special Surgery, Department of Sports Medicine and Shoulder535 E 70th St.New YorkNY10021USA

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Glenoid component positioning in reverse shoulder arthroplasty (RSA) is challenging. Patient-specific instrumentation (PSI) has been advocated to improve accuracy, and is based on precise preoperative planning. The purpose of this study was to determine the accuracy of glenoid component positioning when only the glenoid surface is visible, compared to when the entire scapula is visible on a 3D virtual model.

Methods

CT scans of 30 arthritic shoulders were reconstructed in 3D models. Two surgeons then virtually placed a glenosphere component in the model while visualizing only the glenoid surface, in order to simulate typical intraoperative exposure (“blind 3D” surgery). One surgeon then placed the component in an ideal position while visualizing the entire scapula (“visible 3D” surgery). These two positions were then compared, and the accuracy of glenoid component positioning was assessed in terms of correction of native glenoid version and tilt, and avoidance of glenoid vault perforation.

Results

Mean version and tilt after “blind 3D” surgery were +1.4° (SD 8.8°) and +7.6° (SD 6°), respectively; glenoid vault perforation occurred in 17 specimens. Mean version and tilt after “visible 3D” surgery were +0.3° (SD 0.8°) and +0.1° (SD 0.5°), respectively, with glenoid vault perforation in 6 cases. “Visible 3D” surgery provided significantly better accuracy than “blind 3D” surgery (P<0.05).

Conclusion

When the entire scapula is used as reference, accuracy is improved and glenoid vault perforation is less frequent. This type of visualization is only possible with pre-operative 3D CT planning, and may be augmented by PSI.

Level of evidence

Basic science study. Level III.

Le texte complet de cet article est disponible en PDF.

Keywords : Reverse shoulder arthroplasty, Glenoid component positioning, Accuracy, CT-assisted surgery, Preoperative planning, Patient-specific instrumentation


Plan


© 2017  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 3

P. 407-413 - mai 2017 Retour au numéro
Article précédent Article précédent
  • Hawkins’ type-II talar fracture with subtalar dislocation: A very unusual combination
  • R. Gérard, N. Kerfant, G. Dubois de Mont Marin, R. Stern, M. Assal
| Article suivant Article suivant
  • Results and limitations of humeral head resurfacing: 105 cases at a mean follow-up of 5 years
  • K. Soudy, C. Szymanski, C. Lalanne, C. Bourgault, A. Thiounn, A. Cotten, C. Maynou

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.