S'abonner

Computerized Insulin Order Sets and Glycemic Control in Hospitalized Patients - 18/04/17

Doi : 10.1016/j.amjmed.2016.09.034 
Bertha Wong, MD a, Muhammad M. Mamdani, PharmD, MPH b, c, Catherine H. Yu, MD, MHSc a, b, c, d,
a Department of Medicine, Faculty of Medicine, University of Toronto, Ontario, Canada 
b St. Michaels' Hospital, Toronto, Ontario, Canada 
c Li Ka Shing Knowledge Institute of St. Michael's Hospital, Toronto, Ontario, Canada 
d Dalla Lana School of Public Health, University of Toronto, Ontario, Canada 

Requests for reprints should be addressed to Catherine H. Yu, MD, MHSc, St. Michael's Hospital, 61 Queen Street East, Toronto, ON M5C 2T2.St. Michael's Hospital61 Queen Street EastTorontoONM5C 2T2

Abstract

Background

The purpose of this study was to evaluate the impact of computerized provider order entry subcutaneous insulin order sets on inpatient glycemic control and ordering behavior.

Methods

This was an interrupted time series study of non-intensive care patients at an urban teaching hospital. The primary outcome was proportion of capillary blood glucose in optimal range (4.0-10.0 mmol/L [72-180 mg/dL]) during the 6 months before and after a change to a computerized provider order entry-integrated insulin order set. Secondary outcomes included other measures of glycemia (hyperglycemia [>13.9mmol/L (250 mg/dL)], hypoglycemia [<4.0 mmol/L (72 mg/dL)], severe hypoglycemia [<2.2 mmol/L (40 mg/dL)]) and ordering behavior (use of basal-bolus-correctional insulin regimens). Comparisons of sensitivity-based versus generic correctional scale were also conducted.

Results

A total of 63,393 measurements were obtained from June 2011 to June 2012. Order set usage was limited (51.5%). The weekly proportion of capillary blood glucose within the optimal range was not significantly different after the switch to computerized provider order entry order sets (pre-period: 64.9% vs post-period: 65.3%, P = .996). There were no differences in the proportions of moderate or severe hyperglycemia (pre-period: 10.9% vs post-period: 12.0%, P = .061) and hypoglycemia (pre-period: 1.9% vs post-period: 1.6%, P = .144). However, an increased proportion within the optimal range was seen in those with an order set featuring a sensitivity-based correctional scale versus orders without (65.3% vs 55.0%, P <.001). Increased basal-bolus-correctional ordering was observed after protocol implementation (20.3% vs 23.6%, P <.0001).

Conclusions

With low institutional uptake, computerized insulin order sets did not improve inpatient glycemic control.

Le texte complet de cet article est disponible en PDF.

Keywords : Computerized provider order entry, Diabetes, Glucometrics, Inpatient glucose control, Insulin, Order sets


Plan


 Funding: None.
 Conflict of Interest: None.
 Authorship: All authors had access to the data and a role in writing the manuscript.


© 2016  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 130 - N° 3

P. 366.e1-366.e6 - mars 2017 Retour au numéro
Article précédent Article précédent
  • A Systematic Analysis of Treatment and Outcomes of NOD2-Associated Autoinflammatory Disease
  • Qingping Yao, Bo Shen
| Article suivant Article suivant
  • ‘Urinary Tract Infection’ and the Microbiome
  • Thomas E. Finucane

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.