S'abonner

Ultrasound for the evaluation of soft tissue foreign bodies before and after the addition of fluid to the surrounding interstitial space in a cadaveric model - 21/08/16

Doi : 10.1016/j.ajem.2016.06.004 
Turandot Saul, MD a, , Sebastian D. Siadecki, MD a, Gabriel Rose, DO a, Rachel Berkowitz, MD a, Aaran B. Drake, MD a, Noah Delone, MD a, Nicholas Avitabile, DO b
a Department of Emergency Medicine, Mount Sinai West Hospital, Mount Sinai St Luke's Hospital, New York, NY 
b Department of Emergency Medicine, St Barnabas Hospital, Bronx, NY 

Corresponding Author at: Department of Emergency Medicine, Mount Sinai West Hospital, Mount Sinai St Luke's Hospital., 1000 10th Ave, New York, NY 10019. Tel.: +1 212 523 3981; fax: +1 212 523 2186.Department of Emergency Medicine, Mount Sinai West Hospital, Mount Sinai St Luke's Hospital.1000 10th AveNew YorkNY10019

Abstract

Background

Point-of-care ultrasound may be used to facilitate foreign body (FB) localization and removal. We hypothesized that injection of normal saline adjacent to an FB may make it easier to detect.

Methods

The study was performed on one embalmed human cadaver. Potential FB sites were created of wood (24), metal (24), and null (24). Two sonographers evaluated each of the 72 sites both before and after a 25-gauge needle was inserted into each incision and 3 cc of normal saline was injected. Accuracy, sensitivity, and specificity were calculated both before and after injection of normal saline. Binomial tests were used to determine the statistical significance of FB detection before and after injection. A 2-tailed Student's t test was used to determine if there was a statistically significant difference between the 2 methods.

Results

Preinjection, 116 (81%) of the 144 interpretations (P≤ .001) were correct in their assessment of whether or not an FB was present, with a sensitivity of 81% (95% confidence interval [CI], 72%-88%) and a specificity of 79% (95% CI, 65%-90%). Postinjection, 119 (83%) of these 144 interpretations (P≤ .001) were correct in their assessment of whether or not an FB was present, with a sensitivity of 85% (95% CI, 77%-92%) and a specificity of 77% (95% CI, 63%-88%). This difference was not significant (P=.08; 95% CI, −0.04 to 0.01).

Discussion

Ultrasound was reasonably accurate, sensitive, and specific in identifying 1-cm metal and wood FBs. Although accuracy and sensitivity did improve after normal saline injection, this difference was not significant.

Le texte complet de cet article est disponible en PDF.

Plan


 There is no grant support or involvement.
☆☆ There are no conflicts of interest.


© 2016  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 34 - N° 9

P. 1779-1782 - septembre 2016 Retour au numéro
Article précédent Article précédent
  • New ST-segment algorithms to determine culprit artery location in acute inferior myocardial infarction
  • Xin Huang, Sachin K. Ramdhany, Yong Zhang, Zuyi Yuan, Gary S. Mintz, Ning Guo
| Article suivant Article suivant
  • Increased door to admission time is associated with prolonged throughput for ED patients discharged home
  • Scott P. Krall, Jose Guardiola, Peter B. Richman

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.