S'abonner

Bracing can partially limit tibial rotation during stressful activities after anterior crucial ligament reconstruction with a hamstring graft - 16/08/16

Doi : 10.1016/j.otsr.2016.04.005 
D. Giotis a, N.K. Paschos a, b, , F. Zampeli a, E. Pappas a, c, d, G. Mitsionis a, A.D. Georgoulis a
a Orthopaedic sports medicine center, department of orthopaedic surgery, university of Ioannina, Ioannina, Greece 
b Department of biomedical engineering, university of California, One Shields Avenue, Davis, 95616, CA, USA 
c Discipline of physiotherapy, faculty of health sciences, university of Sydney, Sydney, NSW, Australia 
d Department of physical therapy, Long Island university, Brooklyn campus, Brooklyn, New York, USA 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Hamstring graft has substantial differences with BPTB graft regarding initial mechanical strength, healing sequence, and vascularization, which may imply that a different approach during rehabilitation period is required. The purpose of this study was to investigate the influence of knee bracing on tibial rotation in ACL-reconstructed patients with a hamstring autograft during high loading activities. The hypothesis was that there would be a decrease in tibial rotation in the ACL-reconstructed braced knee as compared to the unbraced knee.

Methods

Twenty male patients having undergone unilateral ACL reconstruction with a semitendinosus/gracilis autograft were assessed. Kinematic data were collected with an eight-camera optoelectronic system during two stressful tasks: (1) descending from a stair and subsequent pivoting; and (2) landing from a platform and subsequent pivoting. In each patient, three different experimental conditions were evaluated: (A) wearing a prophylactic brace (braced condition); (B) wearing a patellofemoral brace (sleeved condition); (C) without brace (unbraced condition). The intact knee without brace served as a control.

Results

Tibial rotation was significantly lower in the intact knee compared to all three conditions of the ACL-reconstructed knee (P0.01 for both tasks). Presence of a brace or sleeve resulted in lower tibial rotation than in the unbraced condition (p=0.003 for descending/pivot and P=0.0004 for landing/pivot). The braced condition resulted in lower rotation than the sleeved condition for descending/pivoting (P=0.031) while no differences were found for landing/pivoting (P=0.230).

Conclusion

Knee bracing limited the excessive tibial rotation during pivoting under high loading activities in ACL-reconstructed knees with a hamstring graft. This partial restoration of normal kinematics may have a potential beneficial effect in patients recovering from ACL reconstruction with a hamstring autograft.

Level of evidence

Level III, case-control therapeutic study.

Le texte complet de cet article est disponible en PDF.

Keywords : Anterior cruciate ligament rehabilitation, Semitendinosus/gracilis, Knee kinematics patellofemoral brace, Prophylactic brace


Plan


© 2016  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 102 - N° 5

P. 601-606 - septembre 2016 Retour au numéro
Article précédent Article précédent
  • Reproducibility of low-dose stereography measurements of femoral torsion after IM nailing of femoral shaft fractures and in intact femurs
  • J. Knafo, T. Thelen, D. Verdier, L. Creppy, C. Tournier, T. Fabre
| Article suivant Article suivant
  • Medial patellofemoral ligament reconstruction for patellar instability following total knee arthroplasty: A review of 6 cases
  • A. Lamotte, T. Neri, A. Kawaye, B. Boyer, F. Farizon, R. Philippot

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.