S'abonner

Computer Aided Abnormality Detection for Kidney on FPGA Based IoT Enabled Portable Ultrasound Imaging System - 08/08/16

Doi : 10.1016/j.irbm.2016.05.001 
K. Divya Krishna , V. Akkala , R. Bharath , P. Rajalakshmi , A.M. Mohammed , S.N. Merchant, U.B. Desai
 WiNet Laboratory, Electrical Engineering Department, Indian Institute of Technology Hyderabad, India 

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose: Ultrasound scanning has been widely used for preliminary diagnosis as it is non-invasive and has good scope for the doctors to analyze many diseases. Due to lack of trained radiologists in remote areas, tele-radiology is used to diagnose the scanned ultrasound data. Availability of online radiographers and having communication facility for the portable ultrasound are issues in tele-radiology for using ultrasound scanning in remote health-care. In these situations, Computer Aided Diagnosis (CAD) will be beneficial in diagnosing the patients with minimal manual intervention.

Methods: We proposed FPGA based CAD algorithm for abnormality detection of kidney in ultrasound images. The proposed algorithm works in the following way: as a pre-processing, an ultrasound image is denoised and region of interest of kidney in ultrasound image is segmented. Intensity histogram features and Haralick features are extracted from the segmented kidney region. Based on extracted features, the classification algorithm is implemented in two stages. In first stage, a Look Up Table (LUT) based approach is used to differentiate between normal and abnormal kidney images. In second stage, after confirming the abnormality, Support Vector Machine (SVM) with Multi-Layer Perceptron (MLP) classifier trained with extracted features is used to further classify the presence of stone or cyst in kidney. The proposed algorithm is implemented on a FPGA based Xilinx Kintex-7 board.

Results: The proposed algorithm gave an accuracy of 98.14%, sensitivity of 100% and specificity of 96.82% in detecting the exact abnormality present in kidney ultrasound images.

Conclusion: The proposed algorithm and its hardware implementation will be beneficial for diagnosing the kidney in absence of radiologists and internet connectivity.

Le texte complet de cet article est disponible en PDF.

Graphical abstract

Le texte complet de cet article est disponible en PDF.

Highlights

Automatic detection of abnormality in kidney is proposed and implemented on FPGA platform.
Texture features from kidney region are used for classification.
Look Up Table approach is used for normal and abnormal classification
SVM classifier is used to detect the exact abnormality present in kidney.
Proposed algorithm resulted with an accuracy of 98.14% in detecting the exact abnormality in kidney.

Le texte complet de cet article est disponible en PDF.

Keywords : Intensity histogram features, Haralick features, FPGA, Cloud, Speckle, SVM kernel


Plan


© 2016  AGBM. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 37 - N° 4

P. 189-197 - août 2016 Retour au numéro
Article précédent Article précédent
  • The Patient Always at the Center: Patient Monitoring, m-Health Solutions, Quality of Data, Networking and Security, Technology Adoption and Innovations
  • Norbert Noury
| Article suivant Article suivant
  • A Reconfigurable Middleware for On-demand Integration of Medical Devices
  • A. Kliem, A. Boelke, A. Grohnert, N. Traeder

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.